EPSON Stylus CX3500/CX3600/CX3650/CX4500/CX4600
9.
Accede to following steps until you've completed the left side PG adjustment.
START
Step 8
Move the Carriage Unit by
using the Timing Belt.
Thickness
Gauge moves?
No
One notch up the Parallel
Adjustment Lever (Left).
Note : "Up" means PG (Platen Gap) narrow.
Figure 5-11. Left Side PG Adjustment
10. Tighten the screw for securing Parallel Adjustment Lever (Left) temporary.
ADJUSTMENT
Note : "Down" means PG
(Platen Gap) wide.
Yes
One notch down the Parallel
Adjustment Lever (Left).
Move the Carriage Unit by
using the Timing Belt.
Yes
Thickness Gauge
moves?
No
Advance to Step 10.
Adjustment Except Adjustment Program
11. Loosen the screw (C.B.S 3x6) for securing the Parallel Adjustment Lever
(Right).
Figure 5-12. Parallel Adjustment Lever (Right) Location
T
Do not remove a screw completely. (two or three revolution)
C A U T I O N
T
You need not to loosen the screw for securing the Parallel
Adjustment Lever (Light).
12. Set the thickness gauge at the position shown by the figure. The thickness
gauge should be placed between the front of the Paper Guide Front Unit and
the center ribs.
Figure 5-13. Placement position for thickness gauge
Revision A
Parallel Adjustment Lever (Right)
C.B.S 3x6
Thickness gauge
171