THE BRUSHES
When brushes
are worn and bristles
do not touch
the edge of a card
held across
the nozzle,
they should
be replaced.
Always
replace
both
brushes
at the same time to
maintain
cleaning
efficiency.
TO REPLACE THE BRUSHES
1
(Disconnect
the Cleaner
from
Electrical
Outlet)
before
re-
placing
brushes.
To replace
worn brushes,
remove
bottom
plate,
belt and
agitator,
following
directions
given on Page 10. Turn
end
plate
of agitator
in opposite
direction
until
one plate
comes
off.
3
Then pry out end section.
4
After
end
section
is removed,,
tap
the
shaft
gently
with
a hammer.
5
Pull
shaft
from
agitator.
12
Remove
brushes
by forcing
out
with screwdriver.
Replace
with
new brushes.
Slide
them into
the channel
and push in as far
as possible.
Replace
shaft,
lining
up the
locator
on shaft
with slot on the
agitator.
Replace
other end
section
and end plate
and
tighten°
Replace
agitator
in
cleaner.
(See Page
11.)