LG ATNH24GPLE2 User Manual page 90

Single zone heat pump 60hz/r410a 6csl0-01b (replaces 6csl0-01a)
Hide thumbs Also See for ATNH24GPLE2:
Table of Contents

Advertisement

SINGLE ZONE
4. Installation of outdoor unit
4.4 Settlement of the outdoor unit
• Anchor the outdoor unit with a bolt and nut tightly and horizontally on a concrete or rigid mount.
• When installing on the wall, roof or rooftop, anchor the mounting base securely with a nail or wire assuming the influence
of wind and earthquake.
• In the case when the vibration of the unit is conveyed to the house, secure the unit with an anti-vibration rubber.
Bolt construction work
Mechanical anchor bolt
Settlement draw of outdoor units
CAUTION
• The ingredients of foundation : Cement : Sand : Gravel for the concrete should 1 : 2 : 4 ratio
• The foundation surface should be finished with mortar.
• The edges of foundation should be rounded.
• A drain passage should be made around the foundation to thoroughly drain water away from the equipment installation
area.
• If installing the outdoor units on the roof, the roof's strength have to be checked.
• Care should be taken for weather - proofing
• Blocking all gaps of outdoor unit, for passing piping and wiring, using sealing material (Field supply)
(Animals and bugs might enter in the machine.)
54 _
Heat pump 60Hz/R410A
M10
Bolt
Diagram of lower surface
Tubing connection
20(25/32)mm(inch)