SINGLE ZONE
1. DC Inverter SINGLE ZONE
1.7 Capacity tables
Models : AUUW24GD2 [LUU247HV] + ATNH24GPLE2 [LCN247HV]
• Cooling Capacity
Outdoor Air
Temperature
68.0 / 57.2
°FDB
TC
SHC
PI
68.0
23.53 19.68 1.05 24.98 19.94 1.43 26.43 20.11 1.55 27.15 20.29 1.56 29.33 20.70 1.56 30.78 21.08 1.55
77.0
22.51 19.05 1.10 23.95 19.34 1.44 25.39 19.55 1.56 26.11 19.74 1.58 28.28 20.18 1.61 29.72 20.59 1.62
89.6
21.13 18.28 1.48 22.57 18.63 1.75 24.00 18.89 1.83 24.72 19.10 1.85 26.87 19.61 1.90 28.31 20.05 1.93
95.0
20.49 17.66 1.65 21.92 18.03 1.87 23.35 18.31 1.94 24.00 18.48 1.91 26.20 19.05 2.00 27.63 19.50 2.04
104.0
19.59 17.12 1.81 21.02 17.53 1.95 22.45 17.85 1.98 23.16 18.08 1.99 25.30 18.66 2.02 26.73 19.13 2.06
109.4
19.05 16.52 1.78 20.48 16.95 1.86 21.91 17.28 1.86 22.62 17.52 1.85 24.76 18.11 1.87 26.19 18.60 1.91
114.8
18.51 16.01 1.59 19.94 16.46 1.61 21.37 16.81 1.58 22.08 17.06 1.56 24.22 17.67 1.56 25.65 18.16 1.60
118.4
17.43 15.23 1.37 18.80 15.68 1.35 20.17 16.04 1.28 20.85 16.28 1.26 22.91 16.89 1.25 24.28 17.37 1.28
• Heating Capacity
Outdoor Air
Temperature
60.8
°FWB
TC
PI
-0.4
19.99
2.14
5.0
20.30
2.12
14.0
21.36
2.07
23.0
23.15
2.16
32.0
24.73
2.33
42.8
27.45
2.49
50.0
29.00
2.59
59.0
31.47
2.76
64.4
32.94
2.85
• Symbol
DB : Dry bulb temperature
WB : Wet bulb temperature
TC : Total capacity
SHC : Sensible capacity
PI : Power Input
(Comp.+ indoor fan motor+outdoor fan motor)
Indoor Air Temperature : °FDB / °FWB
71.6 / 60.8
77.0 / 64.4
TC
SHC
PI
TC
SHC
Indoor Air Temperature : °FDB
64.4
68.0
TC
PI
TC
19.65
2.16
19.40
20.10
2.15
19.96
21.33
2.12
21.32
23.18
2.23
23.19
24.71
2.39
24.65
27.27
2.55
27.00
28.64
2.64
28.45
31.37
2.79
31.43
32.52
2.86
32.22
[°F]
[°F]
[kBtu/h]
[kBtu/h]
[kW]
80.6 / 66.2
PI
TC
SHC
PI
TC
69.8
PI
TC
PI
TC
2.18
19.30
2.20
19.22
2.19
19.91
2.21
19.88
2.17
21.32
2.20
21.32
2.29
23.19
2.32
23.18
2.45
24.60
2.49
24.53
2.60
26.83
2.62
26.63
2.68
28.45
2.70
28.41
2.81
31.22
2.81
30.96
2.86
31.80
2.85
31.32
• Notes
1. All capacities are net. A deduction (cooling mode) or an
addition (heating mode) of Capacity due to operating
heat of indoor unit motor is reflected.
2.
indicates rated capacity at the standard
temperature condition.
- Heating mode Outdoor conditions : 85%RH.
However, the condition on nominal capacity is
7°CDB/6°CWB(44.6°FDB/42.8°FWB)
3. Direct interpolation is permissible. Do not extrapolate.
4. Capacities are based on the following conditions:
- Interconnecting Piping Length : 7.6m(25ft)
- Level Difference : Zero.
86.0 / 71.6
89.6 / 75.2
SHC
PI
TC
SHC
PI
71.6
75.2
PI
TC
PI
2.21
18.92
2.26
2.24
19.64
2.29
2.23
21.12
2.30
2.36
22.90
2.42
2.52
24.33
2.58
2.65
26.42
2.69
2.71
27.94
2.74
2.81
30.61
2.83
2.84
30.47
2.83
Heat pump 60Hz/R410A
_ 9