LG ATNH24GPLE2 User Manual page 30

Single zone heat pump 60hz/r410a 6csl0-01b (replaces 6csl0-01a)
Hide thumbs Also See for ATNH24GPLE2:
Table of Contents

Advertisement

SINGLE ZONE
1. DC Inverter SINGLE ZONE
Models : AUUW42GD2 [LUU427HV] + ATNH42GMLE2 [LCN427HV]
• Cooling Capacity
Outdoor Air
Temperature
68.0 / 57.2
°FDB
TC
SHC
68.0
41.18 34.00 2.25 43.72 34.45 3.05 46.25 34.74 3.30 47.52 35.05 3.33 51.32 35.75 3.33 53.86 36.41 3.31
77.0
39.39 32.90 2.35 41.91 33.41 3.07 44.44 33.77 3.31 45.70 34.10 3.36 49.48 34.86 3.42 52.01 35.57 3.45
89.6
36.98 31.57 3.15 39.50 32.18 3.72 42.01 32.62 3.90 43.26 32.99 3.95 47.03 33.87 4.04 49.54 34.63 4.12
95.0
35.86 30.51 3.52 38.36 31.14 3.99 40.85 31.62 4.14 42.00 31.92 4.07 45.85 32.91 4.27 48.35 33.68 4.35
104.0
34.29 29.58 3.86 36.78 30.28 4.16 39.28 30.83 4.22 40.53 31.23 4.23 44.28 32.22 4.30 46.78 33.04 4.39
109.4
33.34 28.54 3.79 35.84 29.27 3.96 38.34 29.85 3.96 39.59 30.27 3.95 43.34 31.29 3.99 45.83 32.12 4.07
114.8
32.40 27.65 3.40 34.90 28.42 3.44 37.40 29.04 3.36 38.65 29.46 3.33 42.39 30.52 3.33 44.89 31.37 3.41
118.4
30.50 26.31 2.93 32.90 27.08 2.87 35.30 27.70 2.74 36.50 28.12 2.69 40.09 29.17 2.66 42.49 30.01 2.73
• Heating Capacity
Outdoor Air
Temperature
60.8
°FWB
TC
-0.4
34.80
5.0
35.34
14.0
37.18
23.0
40.30
32.0
43.04
42.8
47.77
50.0
50.49
59.0
54.78
64.4
57.34
• Symbol
DB : Dry bulb temperature
WB : Wet bulb temperature
TC : Total capacity
SHC : Sensible capacity
PI : Power Input
(Comp.+ indoor fan motor+outdoor fan motor)
10 _
Heat pump 60Hz/R410A
Indoor Air Temperature : °FDB / °FWB
71.6 / 60.8
PI
TC
SHC
PI
TC
64.4
PI
TC
PI
TC
3.34
34.21
3.36
33.77
3.30
34.98
3.35
34.75
3.22
37.12
3.30
37.11
3.37
40.35
3.47
40.37
3.62
43.02
3.72
42.91
3.88
47.46
3.97
47.00
4.03
49.86
4.11
49.52
4.30
54.62
4.34
54.71
4.44
56.62
4.46
56.09
[°F]
[°F]
[kBtu/h]
[kBtu/h]
[kW]
77.0 / 64.4
80.6 / 66.2
SHC
PI
TC
SHC
PI
Indoor Air Temperature : °FDB
68.0
69.8
PI
TC
PI
3.40
33.60
3.42
3.41
34.66
3.45
3.39
37.11
3.43
3.57
40.37
3.62
3.82
42.82
3.87
4.05
46.70
4.09
4.17
49.52
4.20
4.37
54.35
4.38
4.45
55.36
4.44
• Notes
1. All capacities are net. A deduction (cooling mode) or an
addition (heating mode) of Capacity due to operating
heat of indoor unit motor is reflected.
2.
indicates rated capacity at the standard
temperature condition.
- Heating mode Outdoor conditions : 85%RH.
However, the condition on nominal capacity is
7°CDB/6°CWB(44.6°FDB/42.8°FWB)
3. Direct interpolation is permissible. Do not extrapolate.
4. Capacities are based on the following conditions:
- Interconnecting Piping Length : 7.6m(25ft)
- Level Difference : Zero.
86.0 / 71.6
89.6 / 75.2
TC
SHC
PI
TC
SHC
71.6
75.2
TC
PI
TC
33.46
3.45
32.93
34.60
3.48
34.19
37.12
3.48
36.76
40.35
3.67
39.86
42.70
3.92
42.36
46.36
4.12
45.99
49.46
4.22
48.63
53.90
4.38
53.29
54.52
4.42
53.04
PI
PI
3.51
3.57
3.58
3.77
4.02
4.19
4.26
4.41
4.40

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Atnh42gmle2Auuw24gd2Auuw42gd2

Table of Contents