SLV-SE210B/SE210D/SE210G/SX110A/SX110B
ALIGNMENT AND ADJUSTMENT
5-1. Reference
1) X-Point (Tracking center) adjustment, "Head switching adjustment" and "NVRAM option setting" can be adjusted with remote control.
2) When replacing the Micom (IC601) and NVRAM (IC605 ; EEPROM) be sure to adjust the "Head switching adjustment" and
"NVRAM option setting".
3) When replacing the cylinder ass'y, be sure to adjust the "X-Point" and "Head switching adjustment".
4) How to adjustment.
- Press the "SW718" button on Main PCB to set the adjustment mode.
- If the corresponding adjustment button is pressed, the adjustment is performed automatically.
- If the adjustment is completed, be sure to turn the power off.
5-1-1. Location of adjustment button of remote control
Head Switching Adjustment
("SP/LP" Button)
X-Point (Tracking Center) Adjustment
("5" Button)
NVRAM Option Setting
("MENU" Button)
SECTION 5
1
2
3
4
5
6
7
8
9
0
Fig. 5-1
5-1
5-1-2. Test point location for adjustment mode setting
Fig. 5-2 Main PCB (Top View)
PRESS
5-2