Kenmore 795.58812.900 Service Manual page 28

Table of Contents

Advertisement

5. If ice ejection motor or Hall IC is abnormal, ice ejection motor rotates in normal direction to exercise initial operation.
It resets the ice maker if ice ejection motor or Hall IC is normal.
6. The mold stops for 1 second at maximum tilted conditions.
7. The mold returns to horizontal conditions as ice ejection motor rotates in reverse direction.
8. When the mold becomes horizontal, the cycle starts to repeat:
Water Supply
Ice Making
2-5 Test Function
1. It is to force the operation during operation test, service and cleaning. The test switch is mounted under the automatic
icemaker. The test function starts when the test switch is pressed for more than ½ second.
2. Test button does not work during ice ejection and water supply. It works when it is in the horizontal conditions. If mold is
full of ice during test function operation, ice ejection control and water supply control do not work.
3. If the mold is in the horizontal (normal) position and the TEST switch is pressed for more than ½ second, ice ejection will
being regardless of how frozen the water might be. When the ejection is completed, the ice maker will refill the mold with
water. Consequently, problems related to filling, ejecting and returning to the horizontal position can be checked using the
test switch. When this test is performed, the buzzer will sound and water will fill the mold. Check the icemaker for repair
if the buzzer does not sound.
4. When water supply is completed, the cycle operates normally as follows:
Icemaking
Ice Ejection
5. Remove ice from the icemaker cube mold and press test switch when icemaker cube mold is full of ice as ice ejection and
water supply control do not work when cube mold is full of ice.
2-6 Other functions relating to freezer compartment door opening
1. When freezer door is open, ice dispenser stops in order to reduce noise and ice drop.
2. When freezer door is open during ice ejection and cube mold returning to horizontal condition, ice ejection and cube mold
level return proceed.
3. When freezer door is open, geared motor and cube ice solenoid immediately stop and duct solenoid stops after 5 seconds.
4. Water dispenser stops in order to protect water drop when freezer door is open.
5. Test function operates normally regardless of refrigerator compartment door opening.
Ice Ejection
Mold Returns to Horizontal
Returning to horizontal conditions
Water supply
- 28 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

795.58813.900795.58814.900795.58816.900795.58819.900

Table of Contents