Oki OKIPAGE 4w Maintenance Manual page 72

Led page printer
Hide thumbs Also See for OKIPAGE 4w:
Table of Contents

Advertisement

Category
Category
Status Message
Status Message
Device configuration error
EEPROM Check Error
Option RAM Check Error
Fuser Error
Thermistor Error
Thermister Open Check Error
Thermister Short Check Error
Watch Dog Timeout Error
Table 6-1 (Cont'd)
Status
Status
Display Content
Display Content
Code
Code
60 40
An error occurred during EEPROM check.
60 60
An error occurred during option RAM check.
60 80
A heater timeout error occurred.
60 90
A thermistor error occurred.
60 91
The thermistor is open.
60 92
A thermistor short occurred.
60 C0
A watchdog timeout occurred.
Remedy
Remedy
Replace the main control board. (When replacing the main
control board, also adjust EEPROM data.) (See Section
4.2.4.)
Check the connection of the Option RAM PC board. If the
option RAM PC board is faulty, replace it.
See Section 6.5.2 4.
Replace the thermistor of the heater Assy.
Replace the thermistor of the heater Assy.
Replace the thermistor of the heater Assy.
To release the error display, turn on the power supply again.
Replace the main control board.