8.6.
Removal of the CCD Unit
To prevent the CCD unit from catching the dust and dirt, do not
remove the CCD unit except for replacing.
• Trox driver (T3): RFKZ0334
8.7.
The
Applyment
Method
The grease apply point of lens unit are as follows.
Apply grease additionally in the specified position if necessary.
• Lead screw
- Grease: VFK1850 (Furoyl type)
- Amount of apply: 2 - 4 mg
• Guide pole
- Grease: VFK1829
- Amount of apply: 2 - 4 mg
29
of
Grease