Honeywell T8090A/191108A Owner's Manual page 5

Heating or cooling thermostat and wallplate or heating/cooling thermostat and subbase
Table of Contents

Advertisement

9 PROGRAM PINS. Must be inserted into
24-hour clock dial slots to control program
index wheel.
10 PIN SLOTS. Located on 24-hour dial at
10-minute intervals for program pin
insertion.
11 MANUAL PROGRAM ADVANCE BUTTON.
Allows change from comfort to energy
savings setting and vice versa without
changing the program.
12 HEAT ANTICIPATOR SCALEPLATE.
Calibrated to match the heating system
current draw in amperes.
13 ANTICIPATOR SETTING LEVER. Must be
adjusted to match the heating system
primary control current.
14 MERCURY BULB AND BIMETAL
ELEMENT (2). Provide automatic tempera-
ture control by switching the heating or
cooling system on or off.
5
4
7
9
5
10
8
6
11
13
12
69-0574—2
14
M8691

Advertisement

Table of Contents
loading

This manual is also suitable for:

191108aQ682bT8090a

Table of Contents