For the left pipings
3. Route the indoor tubing with the drain
hose to the piping hole as desired
position.
4. Insert the pipings and the connecting cable
into the piping hole.
5. Insert the connecting cable into the indoor unit.
• Do not connect the cable to the indoor unit.
• Make a small loop with the cable for easy connec-
tion later.
Outdoor
Indoor
Connecting cable
To remove the holder,
press the bottom of the
chassis near the holder
upwards and pull the tab
out of its hole.
Piping
Tubing holder
2
Pull
1
Press
6. Tape the tubing, drain hose and the connecting
cable.
Indoor/outdoor
connecting cable
Connecting
cable
ƒ¡ 27ƒ¡
Taping
Gas side piping
Liquid side piping
Drain hose