10. Soft Dry Operation.

ƒU During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 1¡ , the compres-
sor OFF temperature is the setting temperature minus 0.5¡
ƒU When the room temperature rises over the compressor ON temperature, the operation mode is switched to the
cooling mode.
ƒU When the room temperature falls between the compressor ON temperature and OFF temperature, the opera-
tion mode is switched to the Soft Dry Operation.
In this temperature range, 10min. Dry Operation, 5.5min operation OFF, 1.5min. only fan operation repeat. Dur-
ing 10min Dry operation, even if the room temperature falls below compressor OFF temperature, 10min(MAX)
Compressor ON from starting of Dry operation which includes 4 min. Compressor ON operation below the
comperssor OFF temperature.
ƒU In micom dehumidify mode, control of fan speed is as following.
ROOM TEMP.
SETTING TEMP.+1°C
(COMP. ON)
SETTING TEMP.
(COMP. OFF)
INDOOR FAN
COMPRESSOR

11. Forced operation

ƒU If you lose wireless remote controller, you can operate the unit with forced operation switch.
ƒU The standand conditions are as following.
Operation Mode
FAN Speed
Setting Temp.
Operation
Cooling
¢"
¢"
1 minutes
2 minutes
Selecting
OFF
fan speed
ON
OFF
Cooling Model
Cooling
High
24°C
Dry operation
10 minutes
LOW
LOW
ON
Heat pump Model
Room Temp¡ˆ 24°C
21°C ¡´Room Temp£...24°C
Cooling
High
24°C
ƒ¡ 20ƒ¡
1.5 minutes
5.5 minutes
OFF
LOW
OFF
Room Temp £...21°C
Soft Dry
Low
Room Temp.
maximum
4 minutes
maximum
10minutes
LOW
ON
Heating
High
22°C

Hide quick links: