Display Function; Self-Diagnosis Function - LG LS-P0760CL Service Manual

Room air conditioner
Table of Contents

Advertisement

Display Function

Operation Indicator
• Cooling, Soft Dry, Heating
Timer Indicator
• Timer Mode
Sleep Timer Indicator
• Sleep Mode
Deice Indicator
• Hot-start, Deice
Compressor On Indicator

Self-diagnosis Function

1. Protection of the evaporator pipe from frosting
If the temperature of the indoor pipe is below 0°C after 7 mins from starting the compressor, the compressor
and the outdoor fan is stopped, and then after 3 mins delay of the compressor and the temperature of the
indoor pipe is over 7°C, the compressor and the outdoor fan is reoperated.
2. Thermistor Cut Off or Short
Cut Off/Short : Blinks on and off the operation mode LED. (0.5 sec ON/3 sec OFF)
: Heating Model only
OUTDOOR
: Cooling Model only
ƒ¡ 21ƒ¡