Mechanical Adjustments; Electrical Adjustments - Sony HCD-LX9AV Service Manual

Compact hi-fi stereo system
Table of Contents

Advertisement

SECTION 5

MECHANICAL ADJUSTMENTS

Precaution
1.
Clean the following parts with a denatured alcohol-
moistened swab:
record/playback heads
erase head
capstan
2.
Demagnetize the record/playback head with a head
demagnetizer.
3.
Do not use a magnetized screwdriver for the adjustments.
4.
After the adjustments, apply suitable locking compound to
the parts adjusted.
5.
The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
Mode
Torque meter
FWD
CQ-102C
FWD
CQ-102C
back tension
REV
CQ-102RC
REV
CQ-102RC
back tension
FF/REW
CQ-201B
FWD tension
CQ-403A
REV tension
CQ-403R
pinch rollers
rubber belts
idlers
Meter reading
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
71 to 143 g • cm
(0.98 – 1.99 oz • inch)
100 g or more
(3.53 oz or more)
100 g or more
(3.53 oz or more)
L-CH
peak
SECTION 6

ELECTRICAL ADJUSTMENTS

DECK SECTION
1.
Demagnetize the record/playback head with a head
demagnetizer.
2.
Do not use a magnetized screwdriver for the adjustments.
3.
After the adjustments, apply suitable locking compound to
the parts adjusted.
4.
The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5.
The adjustments should be performed in the order given
in this service manual. (As a general rule, playback circuit
adjustment should be completed before performing
recording circuit adjustment.)
6.
The adjustments should be performed for both L-CH and
R-CH.
7.
Switches and controls should be set as follows unless
otherwise specified.
Tape
Signal
P-4-A100
10 kHz, –10 dB
WS-48B
3 kHz, 0 dB
P-4-L300
315 Hz, 0 dB
Record/Playback Head Azimuth Adjustment
(Deck A, Deck B)
Note: Perform this adjustments for both decks.
Procedure:
1.
Mode : Playback
test tape
P-4-A100
(10kHz, –10dB)
set
2.
Turn the adjustment screw and check output peaks. If the
peaks do not match for L-CH and R-CH, turn the
adjustment screw so that outputs match within 1 dB of peak.
output
within
level
1 dB
R-CH
peak
screw
position
0 dB=0.775V
Used for
Azimuth Adjustment
Tape Speed Adjustment
Level Adjustment
MD OUT
level meter
+
within 1dB
screw
L-CH
R-CH
position
peak
peak
15