Mechanical Adjustments; Electrical Adjustments; Deck Section - Sony HCD-LV60 Service Manual

Table of Contents

Advertisement

SECTION 5

MECHANICAL ADJUSTMENTS

Precaution
1. Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
erase head
capstan
2. Demagnetize the record/playback head with a head demagne-
tizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
Torque Measurement
LekSound.net
Mode
Torque Meter
FWD
CQ-102C
FWD
CQ-102C
back tension
REV
CQ-102RC
REV
CQ-102RC
back tension
LekSound.net
FF/REW
CQ-201B
FWD tension
CQ-403A
REV tension
CQ-403A
LekSound.net
12
pinch rollers
rubber belts
idlers
Meter Reading
3.1~6.96 mN•m
(31 to 71 g•cm)
(0.43 – 0.98 oz•inch)
0.20~0.58 mN•m
(2 to 6 g•cm)
(0.03 – 0.08 oz•inch)
3.1~6.96 mN•m
(31 to 71 g•cm)
(0.43 – 0.98 oz • inch)
0.20~0.58 mN•m
(2 to 6 g•cm)
(0.03 – 0.08 oz • inch)
6.97~14.02 mN•m
(71 to 143 g•cm)
(0.99 – 1.99 oz • inch)
9.80 mN•m
(100 g or more)
(3.53 oz or more)
9.80 mN•m
(100 g or more)
(3.53 oz or more)
SECTION 6

ELECTRICAL ADJUSTMENTS

DECK SECTION

0 dB = 0.775 V
Precaution
1. Demagnetize the record/playback head with a head demagne-
tizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in
this service manual. (As a general rule, playback circuit ad-
justment should be completed before performing recording
circuit adjustment.)
6. The adjustments should be performed for both L-CH and R-
CH.
7. Switches and controls should be set as follows unless other-
wise specified.
8. Set to the DOLBY NR OFF.
9. Set to the test mode.
(1) Press the
?/1
button to turn the power ON.
(2) Select the function "TAPE A or B".
[
(3) Press the button of
[DISC 3]
and
simultaneously, to set the tape deck test mode
and blink the indicator of disc tray number on the fluores-
cent indicator tube.
(4) To exit from the test mode, press the
• Test Tape
Tape
Signal
P-4-A100
10 kHz, – 10 dB
WS-48B
3 kHz, 0 dB
P-4-L300
315 Hz, 0 dB
/CLOCK SET]
[ENTER/NEXT]
,
c
button.
?/1
Used for
Azimuth Adjustment
Tape Speed Adjustment
Playback Level Adjustment
,

Advertisement

Table of Contents
loading

Table of Contents