Honeywell CT3600 Owner's Manual page 23

Seven day programmable heat and/or cool low voltage (20 to 30 vac) thermostat and wallplate
Hide thumbs Also See for CT3600:
Table of Contents

Advertisement

5-WIRE HEAT/COOL
(JUMPER REMOVED)
THERMOSTAT
B
R
HEATING
RELAY OR
VALVE COIL
1
1 POWER SUPPLY. PROVIDE
DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
Notice:
This thermostat is a Class B digital apparatus that complies with Canadian Radio Interference Regulations,
CRC c. 1374.
RC O W Y
G
FAN
COOLING
CONTACTOR
RELAY
COIL
M10619
5-WIRE HEAT/COOL WITH DAMPER
1
1
POWER SUPPLY. PROVIDE
DISCONNECT MEANS AND
OVERLOAD PROTECTION
AS REQUIRED.
23
(JUMPER INTACT)
THERMOSTAT
B
RC O W Y
R
HEAT
HEAT
DAMPER
RELAY
FAN
COOL
DAMPER
RELAY
G
COMPRESSOR
CONTACTOR
1
M18738
69-1642