CBA750B | USER MANUAL Firmware version 4.2
CRADLEPOINT
Failback Configuration (Advanced)
This is used to configure failback, which is the
ability to go back to a higher priority WAN interface
if it regains connection to its network.
Usage: Fail back based on the amount of data
passed over time. This is a good setting for when
you have a dual-mode EVDO/WiMAX modem and
you are going in and out of WiMAX coverage. If the
router has failed over to EVDO it will wait until you
have low data usage before bringing down the EVDO connection to check if a WiMAX connection can be made.
• High (Rate: 80 KB/s. Time Period: 30 seconds.)
• Normal (Rate: 20 KB/s. Time Period: 90 seconds.)
• Low (Rate: 10 KB/s. Time Period: 240 seconds.)
• Custom (Rate range: 1-100 KB/s. Time Period range: 10-300 seconds.)
Time: Fail back only after a set period of time. (Default: 90 seconds. Range: 10-300 seconds.) This ensures that the
higher priority interface has remained online for a set period of time before it becomes active (in case the connection is
dropping in and out, for example).
Disabled: Deactivate failback mode.
Immediate Mode: Fail back immediately whenever a higher priority interface is plugged in or when there is a priority
change. Immediate failback returns you to the use of your preferred Internet source more quickly which may have
advantages such as reducing the cost of a failover data plan, but it may cause more interruptions in your network than
Usage or Time modes.