Sony HCD-GNX700 Service Manual page 20

Sony mini hi-fi component system service manual
Table of Contents

Advertisement

HCD-GNX700/GNX800
[CD SHIP MODE (WITHOUT MEMORY CLEAR)]
• This mode moves the optical pick-up to the position durable
to vibration. Use this mode when returning the set to the
customer after repair.
Procedure:
1. Press
button to turn the set ON.
?/1
2. Select CD function.
3. Press [CD] button and
?/1
will power off automatically.
4. After the "STANDBY" blinking display finish, a message
"MECHA LOCK" is displayed on the fluorescent indicator
tube and the CD ship mode is set.
[CD POWER MANAGE]
• This mode let you switch on or off power supply to the BU
during TUNER function.
• When CD POWER is set to OFF, the power supply to the BU
is cut off during TUNER function. It will increase the time
taken to access CD when function change from TUNER to
CD but it will improve tuner reception.
• When CD POWER is set to ON, the power supply to the BU
is not cut off during TUNER function. It will reduce the time
taken to access CD when function change from TUNER to
CD but it will decrease tuner reception performance.
Procedure:
1. Press
button to turn the set ON.
?/1
2. Select CD function.
3. Press
button to turn the set OFF.
?/1
4. Press x button and
?/1
will power on automatically.
5. The message "CD POWER ON" or "CD POWER OFF" will
be displayed on the fluorescent indicator tube.
20
button simultaneously. The set
button simultaneously. The set
[CD TRAY LOCK MODE]
• This mode let you lock the disc trays. When this mode is
activated, the disc tray will not open when
button or [EX-CHANGE/DISC SKIP] button is pressed. The
message "LOCKED" will be displayed in the will be displayed
on the fluorescent indicator tube.
Procedure:
1. Press
button to turn the set ON.
?/1
2. Select CD function.
3. Press x button and
Z
simultaneously and hold down until "LOCKED" or
"UNLOCKED" displayed on the fluorescent indicator tube
(around 5 seconds).
[VIDEO/MD SWITCHING]
• This mode let you switch from VIDEO to MD and vice-versa.
Procedure:
1. Press
button to turn the set ON.
?/1
2. Select VIDEO function.
3. Press [VIDEO/MD] button and
The function will change to MD. Press the same buttons again
to change from MD to VIDEO.
[TCM OFFLINE MODE]
• This mode prevents set from power off automatically when
TCM is not connected.
Therefore, measurements can be done even when TCM is not
connected during production.
• Procedure:
1. When the system in turned off, press [EQ BAND] button,
[TAPE A/B] button and
set will power on automatically.
2. The message "TCM OFFLINE" will be displayed on the
fluorescent indicator tube.
Z
OPEN/CLOSE
button
OPEN/CLOSE
button simultaneously.
?/1
?/1
button simultaneously. The

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hcd-gnx800

Table of Contents