LG VX9100 Service Manual page 110

Dual band cdma [pcs/cellular/gps] cdma mobile phone
Hide thumbs Also See for VX9100:
Table of Contents

Advertisement

VX9100
START
Check the voltage level at R210
Whether its range is 1.5~2.0V
Check the signal level at
Each side of MIC
Check the soldering of MIC network
MIC will work properly
Copyright © 2007 LG Electronics. Inc. All right reserved
Only for training and service purposes
YES
NO
YES
NO
YES
NO
YES
Checking Flow
Checking Flow
Check the soldering
at R210
YES
Resolder M200
Resolder MIC network
- 109 -
Replace MSM or Main B/D
NO
Resolder R210
LGE Internal Use Only