4. Slide the side curtain frame as close to the air conditioner as necessary to lock the side curtain to the frame.
5.
Repeat above steps for the left-hand side curtain and frame.
Prepare Window for Installation
1.
Measure the width of the window opening.
2.
Mark the center line on the inside windowsill.
Position Air Conditioner
NOTES:
■ Handle the air conditioner gently.
■ Be sure your air conditioner does not fall out of the opening during installation or removal.
■ The place w
here the power cord exits the air conditioner should be no more than 4 ft (122 cm) from a grounded
outlet.
(For model ESA406K,ESA408K,ESA406K-L,ESA408K-L, ESA406K-T,ESA408K-T,ESA408K-E electrical outlet can be
grounded within 6 ft (183 cm))
■ Do not block the louvers in the front panel.
■ Do not block the louvers on the outside of the air conditioner.
1.Center the air conditioner in the window. Lower the window sash behind the top channel to hold the cabinet in
place
NOTE: Your model may differ from the one shown.
ESA412K
A. Width of window opening
B. Center line
9