4. Input an appropriate value for "Up Ramp 16", and click "set".
Check that the power meter registers a change in power level.
5. Repeat step 4 (Input and set) until the target power level is displayed on the power meter.
(Refer to the Calibration Specification table below.)
Calibrating Specification Table
Note that each frequency band is divided into segments and that each segment has a Calibration Channel allocated to it.
Band
Segment
E-GSM
DCS
Calibration
Channel
0 - 0
14
45
0 - 1
0 - 2
124
0 - 3
1007
1 - 0
550
1 - 1
633
1 - 2
775
1 - 3
848
Channel
Calibrating
Range
Order
1 - 25
2
26 - 99
1
100 - 124
4
975 - 1023
3
512 - 600
2
601 - 700
1
701 - 800
4
801 - 885
3
– 8-14 –
Calibrating
Type
5
5 - 19
5
5
0
0 - 15
0