YEAR
Fig. 1. Ultraviolet lamp cleaning reminder schedule.
CAUTION
UV Lamp Burn Hazard.
Harmful to bare skin.
Can cause severe burns.
Disconnect power 15 minutes before removing the ultraviolet lamp(s)
IMPORTANT
If the lamps in your model have external wires running along the glass
surface, be sure to avoid pulling on those wires.
To clean your lamps:
1. Disconnect the power to your HVAC system.
2. Unplug your ultraviolet air treatment system cord from the electrical outlet and
allow the lamps to cool for at least 15 minutes.
3. Rotate your lamp knob counterclockwise and gently pull the lamp knob to
remove the lamp(s).
4. Holding only the lamp knob, wipe the lamp glass using a soft cloth with window
cleaner applied to it. Do not touch the lamp surface with your hands. Use only
the cloth.
5. To ensure that the lamp indicator continues to function, use a moistened cotton
swab to gently remove any dust that may have collected between the lamp light
indicator on the base and the black lamp base.