Sharp R-22GT-F Service Manual page 28

Commercial microwave oven
Hide thumbs Also See for R-22GT-F:
Table of Contents

Advertisement

R-22GT-F
R-22GV-F
5) Practice for cancelling total using times and total operation
time (user and service) and all other counter.
... Flashing /
PAD
DISPLAY
(Door close)
SET
SET
(within 2.0sec.)
DOUBLE QUANTITY
CHECK
SINGLE
SET
OTHER SETTING AND CHECKING PROCEDURE
1. EXPRESS DEFROST
T = STG1 + STG 2 + STG3
STG = A x T + B
1) To set the constants of Express defrost.
(
Ex. 0.20T + 20,
0.13T + 30,
0.67T - 50,
" ": Flicker /
PAD ORDER
(Door close)
SET
SET
"NO"
(within 2 sec.)
#1 START
EXPRESS DEF
2,0
#2 SELECTATIME
2
#4 SELECTAPOWER
4
SELECTATIME
1,3
SELECTATIME
3
#4 SELECTAPOWER
3
SELECTATIME
#3
5
SELECTAPOWER
2
SET
SET
#1 : No key entry signal.
#2 : To set -B, touch the selectapower key twice.
#3 : Ex. defrost is paused after 50% of cooking time has lapsed when 5
key is entered, otherwise it is paused at the end of each stage.
... 0.1sec BUZZER
INDICATOR
TONE
.
.
.
No.
.
.
.
DOUBLE
.
.
.
)
40% at 1st stage
30% at 2nd stage
20% at 3rd stage
: 0.1 sec BUZZER
DISPLAY
TONE
.
.
.
.
0.00
DEF.
0.20 DEF
x 2
(A)
0 DEF
20 DEF
(+ - B)
DEF
P -
DEF
P - 40
0.00 DEF
0.13 DEF
x 2
(A)
0 DEF
30 DEF
(+ - B)
DEF
P -
DEF
P - 30
0 DEF
5 DEF
DEF
P -
DEF
P - 20
. DEF
.
KEY
DISPLAY
0
0
End of each stage
1
1
After 10% of total cooking time is passed
:
:
:
9
9
After 90% of total cooking time is passed
START
A
There is no pause
2) To check the constants of Express defrost.
PAD
CHECK
EXPRESS DEFROST
( pause time )
CHECK
3) To set user counts
Practice for inputting total number of using times (Ex.
3100 times), and using times of Memory 1 (Ex. 100
times).
PAD
(Door close)
CHECK
CHECK
(user total count)
DOUBLE QUANTITY
SIGNAL
SET
3,1,0,0
SET
(user total count 3100 set)
#A
1
(after 1 sec.)
(memory 1 count)
SET
1,0,0
SET
(memory 1 count 100 set)
CHECK
NOTE:
1 : To input using times of other memory, touch necessary Memory key
at above step #A.
2 : To input using times of manual cooking, touch SELECTATIME key
at above step #A.
3 : To input using times of Express Defrost, touch EXPRESS
DEFROST key at above step #A.
26
PAUSE
" ": Flicker /
: 0.1 sec BUZZER
DISPLAY
INDICATOR
.
.
"No." CHECK
0.20
DEF
( A )
20
( +-B )
P - 40
( PL )
0.13
( A )
30
( +-B )
P - 30
( PL )
5
P - 20
( PL )
( repeat )
.
" ": Flicker /
: 0.1 sec BUZZER
DISPLAY
INDICATOR
.
.
.
CHECK No.
82 68
CHECK
0
31 00
31 00
1
No.
1 32
0
1 00
1 00
.
TONE
TONE
x 4
x 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-22gv-f

Table of Contents