Section 8:

Trouble Shooting

Symptom
One or more stations do
not turn on
Stations turn on when
they are not supposed to
One station is stuck
on and will not shut off
All stations do not turn on
Timer will not power up
Stations continue to turn on and off
when they are not programmed to
Persistant Fault
07WTM004225 57932-24 rE.indd 15
Cause
1. Faulty Solenoid
2. Wire broken or not connected
3. Flow control stem screwed down, shutting valve off
4. Programming is incorrect
1. Water pressure is too high
2. More than one cycle is programmed
3. Stations are set to water with both programs
1. Faulty valve
2. Particles of dirt or debris stuck in valve
3. Valve diaphragm faulty
1. Transformer is defective or is not connected correctly
2. Programming is incorrect
3. Timer is in OFF mode
1. Transformer is defective or is not connected correctly
2. Transformer not plugged into an operational AC outlet
3. Timer is not all the way down on the docking port.
1. Multiple cycles are programmed.
2. Excessive pressure
3. Stations are set to water with both programs.
4. Water Budgeting is set to more than 100%
1. Short in wiring or solenoids