4.8 Gamma coefficient of Gamma table "Custom1/2/3" [GammaPower]
Used to switch the gamma coefficient when the gamma table is Custom 1/2/3 and to refer the gamma coefficient.
Target of switching and referencing is followed by setting value of the Gamma bank.
Command code
HEX
0x47
0x50
Parameters
Data length: 1
【Data 0】
HEX
0x30
0x31
0x32
0x33
0x34
0x35
0x36
0x37
0x38
When the projector is not powered on and it receives the command, the projector ignores the command and does not respond.
No response returned when Gamma correction is set to Normal/A/B/C/D.
Table 4-15 GAMMA POWER CMD
ASCII
'G'
'P'
Table 4-16 GAMMA POWER CMD DATA
ASCII
Operation
'0'
'1'
'2'
'3'
'4'
'5'
'6'
'7'
'8'
Function
Gamma coefficient of Gamma table "Custom 1/2/3"
[GammaPower]
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.6
24 / 61
4 Command control
Operation
Reference
PJ04030102B