5. Parameter Address Map
This map indicates address, size, Data (range), Parameter, Description, and Default Value of
parameters which can be transferred using and "Data set 1 (DT1)."
All the numbers of address, size, Data, and Default Value are indicated in 7-bit
Hexadecimal-form.
■Address Block map (GS Part: Model ID = 42H)
An outlined address map of the Exclusive Communication is as follows;
Address (H) Block
40 00 00
+-----------------------+
| SYSTEM PARAMETERS
40 01 3F
+-----------------------+
40 1x 00
+-----------------------+
| PART PARAMETERS
|(x = 0-F)
40 2x 5A
+-----------------------+
41 m0 00
+-----------------------+
| SRUM SETUP PARAMETERS | Individual
|(m = 0-1)
41 m8 7F
+-----------------------+
48 00 00
+-----------------------+
| SYSTEM PARAMETERS
48 01 10
+-----------------------+
| PART PARAMETERS
48 1D 0F
+-----------------------+
49 m0 00
+-----------------------+
| DRUM SETUP PARAMETER
|(m = 0-1)
49 mE 17
+-----------------------+
There are two ways in which GS data is transmitted: Individual Parameter Transmission in
which individual parameters are transmitted one by one, and Bulk Dump Transmission in
which a large amount of data is transmitted at once.
| Individual
| Individual
|
|
| Bulk
| Bulk
|Bulk
|
10