Connecting (Cabling) Each Mvp; Testing Signal And Power Connections; Using The Mvp™ Ta8 Curve Test Button - Chauvet MVP Ta8 Curve User Manual

Modular video panel
Table of Contents

Advertisement

Connecting (Cabling) Each MVP™

6. Connecting (Cabling) Each MVP™
Testing Signal and
Power Connections
Power Out
Signal Out
Using the MVP™
Ta8 Curve Test
Button
MVP™ Ta8 Curve User Manual, Rev. 1
Each MVP™ Ta8 Curve has two (2) power supply sockets and two (2) signal sockets.
• The Power and Signal IN are located on the upper right-hand side of each panel.
• The Power and Signal OUT are located on the upper left-hand side of each panel.
• The Signal IN and OUT may be used interchangeably.
Each MVP™ Ta8 Curve has LED indicator lights.
• Each panel indicates a successful power connection when the Power indicator light
remains red.
• Each panel indicates video signal reception when the Link LED indicator light
displays green. This light should be blinking rapidly to indicate good reception.
Power Indicator LED
Each MVP™ Ta8 Curve also has a Test button, used to ensure all LEDs in each panel
are functional. Use the Test Button on each panel to perform a self-test. If self-testing,
you must perform the test individually for each MVP™ Ta8 Curve. You do not need to
connect to a signal or use software.
When using the Test button, make sure the MVP™ Ta8 Curve is not connected to
the VIP™ Driver.
To use the Test button, you must connect the power, but do not connect the signal
cables. Press the Test button to toggle through various LED light display configurations.
Power In
Signal In
Link Indicator LED
Test Button
11

Advertisement

Table of Contents
loading

Table of Contents