SPEAKER
AUTO
TURN ON
INPUT
OUTPUT
+
12V DC AUD O
OFFSET
INPUT
LEVEL
LO
HI
d24"
(60cm)
bare-metal
chassis ground
woofer
OPERATION
SPEAKER
+
Automatic Turn-On Selection: The IX series offers three different automatic turn-on modes that can be
selected on the end panel; +12V, DC Offset, and Audio. Using either the DC Offset or Audio mode causes the
REM terminal to have +12V out for turning on additional amplifi ers.
• Remote Turn-On: Set the switch to +12V to use the remote turn-on lead from your source unit. Run 18
gauge wire from the Remote Turn-On Lead on your source unit to the terminal labeled REM between the
amplifi er's positive and negative power terminals. This is the preferred automatic turn-on method.
• DC Offset Turn-On: If Remote Turn-On is not an option, the next best setting is DC Offset. The DC Offset
mode detects a 6V DC offset from the HI-Level speaker outputs when the source unit has been turned on.
• Signal Sense Turn-On: The Audio setting is the fi nal alternative for Automatic turn-on. This is a Signal Sense
turn-on method that detects the incoming audio signal from your source unit and automatically turns on the
amp. This turn-on method will not work properly if the input gain control is not set appropriately.
4
POWER
GND
REM
+12V
L
REMOTE BASS
R
external fuse
remote turn-on
(see page 5)

MONO OPERATION

minimum impedance of 2 ohms
AUTO
TURN ON
INPUT
OUTPUT
12V DC AUDIO
L
OFFSET
INPUT
LEVEL
R
LO
HI
IX AMPLIFIERS
d18"
(45cm)
external fuse
POWER
GND
REM
+12V
REMOTE BASS
12V
battery

Hide quick links: