5. Electrical Adjustments - Sony MXD-D400 Service Manual

Compact disc minidisc deck
Hide thumbs Also See for MXD-D400:
Table of Contents

Advertisement

5. SELECTING THE TEST MODE
There are 26 types of test modes as shown below. The groups can be switched by turning the
the group to be used, press the
modes.
Refer to "Group" in the table for details can be selected.
All items used for servicing can be treated using group [Service]. So be carefully not to enter other groups by mistake.
Note: Do not use the test mode in the [Develop] group.
If used, the unit may not operate normally.
If the [Develop] group is set accidentally, press the
Display
No.
AUTO CHECK
C01
Automatic self-diagnosis
Err Display
C02
Error history display, clear
TEMP ADJUS
C03
Temperature compensation offset adjustment
LDPWR ADJUS
C04
Laser power adjustment
Iop Write
C05
Iop data writing
Iop NV Save
C06
Writes current Iop value in read nonvolatile memory using microprocessor
EF MO ADJUS
C07
Traverse (MO) adjustment
EF CD ADJUS
C08
Traverse (CD) adjustment
FBIAS ADJUS
C09
Focus bias adjustment
AG Set (MO)
C10
Auto gain output level adjustment (MO)
AG Set (CD)
C11
Auto gain output level adjustment (CD)
TEMP CHECK
C12
Temperature compensation offset check
LDPWR CHECK
C13
Laser power check
EF MO CHECK
C14
Traverse (MO) check
EF CD CHECK
C15
Traverse (CD) check
FBIAS CHECK
C16
Focus bias check
ScurveCHECK
C17
S-curve check
VERIFYMODE
C18
Nonvolatile memory check
DETRK CHECK
C19
Detrack check
0920 CHECK
C25
Most circumference check
Iop Read
C26
Iop data display
Iop Compare
C27
Comparison with initial Iop value written in nonvolatile memory
ADJ CLEAR
C28
Initialization of nonvolatile memory for adjustment values
INFORMATION
C31
Display of microprocessor version, etc.
CPLAY 2MODE
C36
Continuous playback mode
CREC 2MODE
C37
Continuous recording mode
• For details of each adjustment mode, refer to "SECTION 5. Electrical Adjustments".
For details of "Err Display" (C02), refer to "Self-Diagnosis Function" on page 2.
• If a different mode has been selected by mistake, press the
• Modes with (×) in the Mark column are not used for servicing and therefore are not described in detail. If these modes are set acciden-
[MENU/NO]
tally, press the
[YES]
button. After setting a certain group, turn the
[MENU/NO]
Details
button to release the mode immediately.
[
AMS
l
button immediately to exit the [Develop] group.
[MENU/NO]
button to release that mode.
MXD-D400
[
AMS
]
l
L
(MD) knob. After selecting
]
L
(MD) knob switches between these
Group
Mark
Check
Service
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents