5-1. GENERAL
In this set, CD and MO discs can be automatically adjusted by set-
ting the Overall Adjustment mode within the TEST MODE,
Before performing these automatic adjustments, it is necessary to
clear the memory, adjust the power charge and temperature in the
Manual mode.
5-2. NOTES FOR ADJUSTMENT
5-2-1. Jigs
• CD disc
TDYS-1 (part code: 4-963-646-01)
• MO disc
PTDM-1 (part code: J-2501-054-A)
• Digital voltmeter
• Thermometer
5-2-2. Adjustment sequence
The adjustments should be always performed in the following
sequence:
1 NV Initialize
(Clear the Non-Volatile memory)
2 Power supply voltage adjustment
Charge adjustments
3
Temperature adjustment
4
5 Overall CD adjustments
6 Overall MO adjustments
RESUME clear
7
5-2-3. Power
The power is supplied with 3.0 V DC from the charge stand.
Note: Be sure to place the set horizontally on the overall
adjustment.
5-3. NV Initialize
(Clear the Non-volatile memory)
5-3-1. How to NV Initialize
1. Set the Test mode.
2. Press the
kye and set the Overall adjustment.
VOL –
3. Press
key on the remote control.
LCD display
000 Res OK?
4. Press
key on the remote control again.
LCD display
000 Res ***
021 Res!
5. Press
key. to terminate the Manual mode and return to the
x
Overall adjustment mode.
Note: The power, charging and temperature adjustment settings are
not cleared during NV initialize.
SECTION 5

ELECTRICAL ADJUSTMENTS

Overall adjustment mode
Manual mode
Overall adjustment mode
Manual mode
After initialize is completed.
5-3-2. Changing Adjustment values
Adjustment settings are cleared when NV initialize is performed.
So right after performing NV initialize you must rewrite the correct
data according to the microcomputer version.
• Adjustment value change method
5-3-3 Adjustment value change method
(when using Version 1.000)
1. In test mode press the
VOL +
mode.
2. Set 861 as the item number.
LCD display
861 VarB1k 00
3. Press the
key.
4. Press the
key and set 862 as the item number.
>
LCD display
862 VarWrt 00
5. Press the
key, and set in Adjustment Change mode.
862 88C6
This section (address) flashes.
6. Press the
key.
x
LCD display
862 88C6
7. Press the
and
VOL +
VOL –
flashing data section while referring to the adjustment data change
list.
LCD display
862 88C6
8. Press the
key. and the address section starts flashing.
9. Press the
key and set the next adjustment address.
VOL +
LCD display
862 88C7
-
This section (address) flashes.
10.Press the
key.
x
LCD display
862 88C7
11.Repeat the adjustments in items 6 - 9 and set up through address
88D1 while referring to the Adjustment Data Change List.
MZ-E710
key and then switch to Manual
FF
FF
This section (data) flashes.
keys and set the value in the
2B
Data value.
FF
FF
This section (data) flashes.