Electrical Adjustments - Sony MZ-DH710 Service Manual

Portable md player
Table of Contents

Advertisement

MZ-DH710
1. PRECAUTIONS FOR ADJUSTMENT
1. Adjustment must be done in the test mode only. After adjusting,
release the test mode. A key having no particular description
in the text, indicates a set key. Also, for the LCD display, the
LCD on the set is shown.
2. Use the following tools and measuring instruments.
• Digital multi meter
• Regulated dc power supply (two sets)
• Thermometer
• Laser power meter
• CD adjustment disc TDYS-1 (Part No. : 4-963-646-01)
• MD1/HiMD1 hybrid adjustment disc MDW-74/GA2
(Part No. : J-2503-022-A)
• Hi-MD3 adjustment disc HMD1GSDJ
(Part No. : 8-892-388-38) *1
*1) Hi-MD3 adjustment disc (HMD1GSDJ) is consumable.
Therefore if it is used 400 times, exchange it for a new.
2. ADJUSTMENT SEQUENCE
Adjustment must be done with the following order.
Adjustment order:
1. Entering the test mode
Note: Enter the test mode with a key.
2. Initialize the adjustment value
3. Setting the temperature correction value
4. Power supply voltage adjustment
5. Laser power check
6. Setting the adjustment values
7. Servo Overall adjustment
8. Resume clear
9. Releasing the test mode
3. ADJUSTMENT OF THE EACH ITEM
3-1. Initialize The Adjustment Value
Procedure:
1. In the test mode (Display Check mode), press the [VOL--] key
to enter the Overall adjustment mode.
2. Press the [DOWNLOAD] key and display "911 ResOK?".
3. Press the
key to display "911 Reset!" and initialize the
X
adjustment values.
4. Press the
key and back to Display Check mode.
x
3-2. Setting The Temperature Correction Value
Procedure:
1. Enter the test mode (Display Check mode).
2. Press the [VOL+] key to enter the Manual mode.
3. Press the
key twice, and press the [VOL+] key twice to
>
display as follows.
Display
0130
Temp
4. Press the
key once to select the item number 0131 and
>
display as follows.
Display
0131
###S**
adjustment value (hexadecimal)
16
SECTION 5

ELECTRICAL ADJUSTMENTS

3-3. Power Supply Voltage Adjustment
Adjustment must be done with the following order.
3-3-1. Setting
Procedure:
3-3-2. PwrAdj adjustments
Repeat the following procedures and adjust all contents of "table 3-
3-1. PwrAdj Specifications".
Procedure:
5. Measure the ambient temperature.
6. Adjust with [VOL+]/[VOL--] keys so that the adjusted value
(hexadecimal value) becomes the ambient temperature.
(example: 25 °C = 19h)
7. Press the
to write the adjusted value.
X
8. Press the
key four times and back to the Display Check
x
mode.
1. Apply the voltage of 1.2 V to the battery terminals, and enter
the test mode (Display Check mode).
2. Press the [VOL+] key to enter the Manual mode.
3. Press the [VOL+] key twice to display as follows.
Display
2000
POWER
key once, press the [VOL+] key once, and press
4. Press the
>
the
key once again to display as follows.
>
Display
2210
PwrAdj
5. Repeat the next procedures (3-3-2. PwrAdj Adjustments), and
adjust all contents of "table 3-3-1. PwrAdj Specifications".
Example Display (Item No. 2211)
2211
**
adjustment value (hexadecimal)
1. Connect the digital multi meter to measuring point (refer to
the following table) and CL433 (GND).
2. Press the
key to change the item numberr to 2211.
>
3. Adjust with [VOL+]/[VOL--] keys so that the value of digital
multi meter becomes specification value.
4. Press the
key to write the adjusted value. (Shifts to the
X
next item automatically)
5. Repeat adjustment from step 3 until item number 2233.