Idle Current Test - HTC Converce Service Manual

Converce
Table of Contents

Advertisement

Doc. Title

Idle current test

Sleep current test
If current consumption is passed at both of idle and sleep mode, it means M/B is
GOOD. If there is any item FAILED at idle or sleep mode, it means M/B is failed,
HTC CONFIDENTIAL
HTC Corporation.
.
Converse Service Manual
please replace M/B for repair.
Issued Date
Revised Date
2. Press Power button to turn on the
Device
3. In "main page", Check phone status,
Click "Turn on Airplane mode"
Set the unit to :
* Airplane mode
* Make sure all RF function is off (phone,
BT, Wifi..)
4. Measure Idle mode current. Idle current
value must under 220mA, if over the
criteria, it means M/B failed, please
replace M/B for repair.
default / KB LED off / GSM standby / WiFi off / BT off)
5. After idle current checked, Switch OFF
the unit. Unit is turn off and no display.
sleep current value must under 20mA, if
over the criteria, it means M/B failed,
please replace M/B for repair.
Conclusion:
Doc. No.
DOC-00044120
2008/07/17
2009/01/15
Page
56 of 78
(condition : Display on / BL
SM-TP002-0706
REV.
A03

Advertisement

Table of Contents
loading

Table of Contents