TEST PROCEDURES
(CONT'D)
PROCEDURE
LETTER
COMPONENT
TEST
WEIGHT
SENSOR
ASSEMBLY
AND
IC3(MEMORY)
TEST.
After
replacing
the
weight
sensor
or IC3, carry
out the
following
procedure
in
order
to calibrate
the weight
sensor.
food
mav be over or under
cooked.
If the weight
sensor
is not recalibrate,
the
The following
procedure
should
be carried out with microwave
oven in a fully
assembled
condi-
tion (with
outer case fitted).
1.
Place the turnrable
on the turntable
support
plate correctly,
and close the door.
2.
Plug the oven into a power point.
("88:88"
will appear on the display.)
3.
Press the STOP/CLEAR
pad. (Display
shows M :
II with sound of buzzer.)
4.
Press the AUTO START/CLOCK
pad.
(Display
shows fl
5.
Press the GRILL pad. (Display
shows II
0~)
0"
with sound of buzzer.)
6.
Press the POWER LEVEL pad.
(Display
shows fl
0~)
7.
Press the INSTANT
COOK/START
pad.
(Display
shows
" TEST"
with sound of buzzer.)
8.
Press the "4" of number pads.
(Display
shows N
DISH"
and oven lamps come on.)
with sound of buzzer, and tuntable
9.
After 13 seconds,
make sure that the display
shows
"25000
-
35000""
with
sound
of
buzzer.
If display
shows
less than
25000
or more than 35000,
weight
sensor
10. Place the weight
2 Kg +2Og (water
load 2 Kg +2Og)
on the turntable.
is defect.
11. Press the "6" of number pads.
(Display
shows M
DISH"
and oven lamps come on.)
with sound of buzzer, and turntable
12. After 13 seconds,
make sure that the display
shows
"02300
-
02800""
with
sound
of
-
buzzer.
If display
shows
less than 02300
or more than 02800,
weight
sensor
is defect.
13. Disconnect
the oven from power supply,
and repeat above procedure
items 1 to 7
14. Press the "7" of number pads, and make sure that the display shows
"02300
- 02800"R.
If display
shows
less than
02300
or more than 02800,
IC3 is defect,
12