Disassembly Instructions
10. POWER CORD
1. Remove the control box. (Refer to section 3)
2. Unfold the control box. (Refer to section 9)
3. Disconnect the grounding screw from the control
box.
4. Disconnect 2 receptacles.
5. Remove a screw which fastens the clip cord.
6. Pull the power cord. (See Fig. 13)
7. Re-install the component by referring to the
removal procedure, above.
(Use only one ground-marked hole
connection.)
8. If the supply cord of this appliance is damaged, it
must be replaced by the special cord.
(The special cord means the cord which has the
same specification marked on the supply cord fit-
ted to the unit.)
11. THERMOSTAT
1. Remove the control box. (Refer to section 3)
2. Unfold the control box. (Refer to section 9)
3. Disconnect the theristor terminals from main
P.W.B assembly.
4. Remove the thermostat. (See Fig. 14)
5. Re-install the components by referring to the
removal procedure, above.