Friedrich UE10 Installation & Operation Manual
Friedrich UE10 Installation & Operation Manual

Friedrich UE10 Installation & Operation Manual

115/230 volts thru-the-wall series

Advertisement

J_'
m
Jl'
m
II'
Installation & Operation Guide
_%
Thru-the-Wall Series
115 Volts • UE08
230 Volts oUE10
oUE12
Model
information
can be found on the name plate on the front of the unit.
To register your application,
complete
and mail the enclosed
registration
card, or
register
on-line at www.friedrich.com
(USA only).
For your future convenience,
record
the model
information
here.
MODEL
NUMBER
SERIAL
NUMBER
PURCHASE
DATE
920-136-01
(01/05)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UE10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Friedrich UE10

  • Page 1 To register your application, complete and mail the enclosed registration card, or register on-line at www.friedrich.com (USA only). For your future convenience, record the model information here.
  • Page 2: Read This Manual

    READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the trouble shooting section.
  • Page 3: Safety Precautions

    Safety Precautions To prevent injury and property damage, the following instructions must be followed. • Ignoring instructions and incorrectly operating the unit can cause harm or damage. The seriousness is classified by the following indications. WARNING " This symbol indicates the possibility of death or serious injury. CAUTION .
  • Page 4 • They are sharp and may cause • Water may enter the unit and • Since the fan rotates at high an injury. damage the insulation. speed during operation, it may cause an injury. • Do not use this air conditioner •...
  • Page 5: Electrical Data

    Electrical Data Electrical Data 115V~ 230V ~ Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button.
  • Page 6 Operating Instructions The controls will look like one of the following: Controls- Cooling Only Models - Turns air conditioner off. Med Fan Only - Med speed fan operation without cooling. Low Fan Only - Low speed fan operation without cooling. High Cool - Cooling with high speed fan operation.
  • Page 7 The controls will look like one of the following: Controls- Cooling & Heating - Turns the air conditioner off. Fan Only - The low fan speed operation without cooling/heating. Low Cool - Cooling with the low speed fan operation. High Cool - Cooling with the high speed fan operation.
  • Page 8: Ventilation Control

    Additional controls and important information. Ventilation Control Push the lever to the "CLOSE" position to cool, heat or recirculate room air only. Pull the lever to the "OPEN" position to exhaust smoke or stale air from the room. This feature is best used in conjunction with the FAN ONLY position. PULL OPEN/PUSH CLOSE...
  • Page 9: Care And Maintenance

    Care and Maintenance TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET. Air Filter Cleaning The air filter should be checked at least twice a month to see if cleaning is necessary. Trapped particles in the filter will build up and block the airflow. This reduces the cooling capacity and can also cause an accumulation of frost on the cooling coils.
  • Page 10 Parts Learning part name prior to installation will help you understand the installation procedure. Parts The Unit The Sleeve with the Rear Grille (sold separately) 1. CABINET 11. EVAPORATOR 2. HORIZONTAL AIR DEFLECTOR 12. CONDENSER (Vertical Louver) 13. COMPRESSOR 3. VERTICAL AIR DEFLECTOR 14.
  • Page 11: Installation Requirements

    All wall sleeves used to mount the new air conditioner must be in good structural condition and have a rear grille to securely attach the new air conditioner. (FIG. 1) Installing the FRIEDRICH USC sleeve ensures optimal 2 Size options performance of the new air conditioner.
  • Page 12: How To Install

    Conditioner must be in sound structural condition and have a rear grille that securely attaches to sleeve, or rear flange that serves as a stop for the Installing the FRIEDRICH USC sleeve ensures Air Conditioner. optional performancesof the unit. If you decide to keep the existing wall sleeve, you Remove old air conditioner from existing wall sleeve.
  • Page 13 PROCEDURE Ptastic rear grille SteeI rear ( If you are using the new sleeve (optionally supplied with your unit),skip to step 3. Otherwise, install the plastic grille from the kit. Cut the plastic grille to 25-112" wide and 15-114" high. Place the plastic grille to the inside of the wall sleeve at the rear flange.
  • Page 14 PROCEDURE Remove the backing from the Horizontal Insulation strip 13/8 '' x 5/e" x 273/16" and attach that to the inside bottom of the sleeve as shown Redirect the louvers at the back of the wall sleeve to 60 ° angle as shown in the FIG 9.
  • Page 15 PROCEDURE B CONTINUED HRemove the backing from the support blocks and attach them to the inside of the wall sleeve as shown FIG 15. Slide the baffle into slots of the support blocks. 5//6'*) _/all Vail Front Block FIG. 15 _1_ Install the new unit into the wall sleeve.
  • Page 16 PROCEDURE Remove the backing from the Horizontal Insulation strip 13,8" x 138" x 273,16" and attach that to the inside bottom of the sleeve as shown Redirect the louvers at the back of the wall sleeve to 60 ° angle as shown in the FIG 16.
  • Page 17 PROCEDURE C CONTINUED • Air conditioners coveredin this manualposean Remove the backing from the 13" shim strips and attach them as shown below in Fig. 22. excessiveweighthazard.Two or morepeopleare needed to moveand installthe unit. The higher portion of shim is to be placed front of the rib on the base of wall sleeve.
  • Page 18: Troubleshooting Tips

    Before you call for service... Trouble Shooting Tips Troubleshooting Tips Save Time and Money! Review the chart below first and you may not need to call for service. Normal Operation • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy clays or when the humidity is high.
  • Page 19 FRIEDRICH, or acts of God. OBTAINING WARRANTY PERFORMANCE: Service will provided FRIEDRICH...
  • Page 20 Memo...
  • Page 21 FRIEDRICH AIR CONDITIONING CO. INC. PO Box 1540 • San Antonio, Texas 78295-1540 4200 N. Pan Am Expressway • San Antonio, Texas 78218-5212 (210) 357-4400 ° FAX (210)357-4490 Visitenos en Internet: www.friedrich.com Impreso en Corea P/NO.: 3828A20436R 920-136-01(01/05)

This manual is also suitable for:

Ue08Ue12

Table of Contents