Download Print this page

Installation - Panasonic DBS 824 Manual

Section 320 dbs 824 to dbs interconnection
Hide thumbs Also See for DBS 824:

Advertisement

Installation

Installation
1. Set SW1 on the CBL-M card according to the following table.
Table 3.
CBL-M switch settings
Master
DBS 40
DBS 72
DBS 96
2. Install the circuit cards according to the layouts shown in the Figures 1
Note: The port numbers for each slot are fixed.
3. Using the cables provided, connect the CBL-M card in the master cabinet
4. Connect the green ground lead on each of the DBS cables to a side frame
6
Section 320 - DBS 824 to DBS Interconnection Supplement
System
Combinations
Slave
1
DBS 824
ON
DBS 824
ON
DBS 824
OFF ON
through 3.
to the CBL-S card installed in the slave cabinet. The cables should be
connected with the green ground cables located at the CBL-M card.
Note: The EMI filter must be installed as close to the cabinet as possible,
as shown in Figure 4 on page 7.
screw on the DBS cabinet.
DBS Manual - Revised April 2000
Switch
Settings
2
3
4
5
ON
ON
ON
ON ON
OFF ON
ON
ON ON
OFF ON
ON OFF OFF OFF
6
7
8
OFF ON
OFF OFF
DBS-2.3/9.2-320