Regeneration Interval - This setting is used to set the
days between regeneration in time clock mode. It is also
active in meter or Aqua-Sensor
backup DIP switch # 10 is set to on. The display will
show "REGEN" icon and "dAYS" as well as the numbers
to change. Adjust the value with the "Up" or "Down"
keys.
Pressing the "Program" key will save the setting and move to the next programming step.
Hardness Setting - This setting is used to set the
hardness (grains) of the influent water supply. For English
Units the display will first show "Hard" for two seconds
and then display the Hardness default (or the previously
programmed value). Adjust the value with the "Up" or
"Down" keys.
(These settings will not get saved to EEPROM until the 'Program' key is pressed while at the
'View' programming step)
Iron Setting (flow meter only) - This setting is used
to set the iron level of the influent water supply. The
display will show "Iron" in the left most digits and the iron
default setting (or the previously programmed value) in the
far right digit. The display will only appear if a flow meter
is connected to the circuit board and the control is set to
Gold. If the iron level is set to "Y", the Efficiency Mode is
inactive. Adjust the value with the "Up" or "Down" keys.
Pressing the "Program" key will temporarily store the setting and move to the next programming
step. (This setting will not get saved to EEPROM until the 'Program' key is pressed while at the
'View' programming step)
Pressure Setting - This setting is used to set the influent
water pressure. The display will show "LowP" in the
left most digits and the pressure default setting in the far
right digit. If the pressure is less than 40 psi, chose "Y".
By choosing "Y" the brine rinse time will be extended.
Adjust the value with the "Up" or "Down" keys.
Pressing the "Program" key will temporarily store the setting and move to the next programming step.
Salt Type (flow meter only) - This setting is used to select the regeneration salt type
(softener mode only). This display will only appear if dips# 3 & 4 are set to Gold, Platinum, or
Other. The display will show "SALt" for 2 seconds. Then display the default 'NACL'. Pushing
the "Up" or "Down" keys will change to 'KCL'.
Pressing the "Program" key will temporarily store the setting and move to the next programming
step. (This setting will not get saved to EEPROM until the 'program' key is pressed while at the
'View' programming step)