LG ABNW366KSA1 Service Manual page 53

Ceiling duct type air conditioner
Hide thumbs Also See for ABNW366KSA1:
Table of Contents

Advertisement

3) Troubleshooting CH04
Display
Title
code
Drain pump
04
/ Float switch
CN Float
0
Check the resistance
Check Point
1. Check the wire connection. (Open, Soldered poorly) ¡ Repair the connection or change the PCB.
2. Check the resistance of float switch (Abnormal : Open, Normal : short) ¡ Check the float switch.
3. Check the level of water
4. Check the volt. Of Drain pump power supply. (AC 230V) ¡ Repair or Change the main PCB.
Cause of error
• Float switch Open.
(Normal : short)
CN-Float
Cycle Troubleshooting Guide
Check point & Normal condition
• The connection of wire(Drain pump/ Float switch)
• Drain pump power input. (220V)
• Drain tube installation.
• Indoor unit installation. (Inclination)
CN-D/PUMP
Service Manual 53

Advertisement

Table of Contents
loading

Table of Contents