GENERAL SAFETY INSTRUCTIONS

Gas bottle
Gas Bottle with 15 kg of maximum capacity can be installed.
Changing of gas bottle must not be carried out in the presence of a naked flame.
Use the gas bottle always in upright position. If a screw on regulator is used ensure that the
regulator washer is present and in good condition -replace if in any doubt.
To place the bottle in position, remove the rear panel which faces the inside during tran-
sport, by unfastening the screws; than put the bottle in position and replace the panel.
Important
Dear client:
when using the radiant heater as a portable appliance, before filling the gas bottle, remember to
discarge the compressed air that may be contained in it.
Pressure regulators, rubber tubes and clips
CHECK that tubing is completely over the
nozzles at each end of the tubing and that it
is held firmly in place by tube clips (See
fig.5). Examine flexible tubing regularly and
get your Dealer to fit new tubing 400 mm
long complying to local standard, if peri-
fig. 5
shed, worn or damaged. Ensure that the rub-
ber tube inserted in the plastic support (see fig. 6). When connecting
the pressure regulator to the gas bottle avoid undue twisting of the flexi-
ble tubing. A 28 ÷ 30 mbar (11.2 in w.g.) pressure regulator for
Butane or Propane complying to local standard must be connected to
the appliance with the above tubing, using suitable tube clips.

Room ventilation

USE ONLY IN A WELL VENTI-
LATED ROOM
Adequate ventilation must be provi-
ded in rooms in which the heater is
used. This ensures removal of the
products of combustion and allows
the entry of replacement air.
The following table shows the smal-
lest size of room suitable for each
heat setting and the dimensions of
the aperture which must be provi-
ded equally divided between high
and low level.

SAFETY GUARD

The guard is to prevent risk of fire
and no part of it should be permanently removed. It does not give full protection for
young children or the infirm.
4
Room
Size
Control knob setting
IH-IHF
Position
small flame
15 m
(low rate)
Position
28.5 m
medium flame
(medium rate)
Position
big flame
42 m
3
(maximum rate)
fig. 6
Room
Room
Size
Aperture
IH2-IHF2
3
105 cm
3
42 m
3
2