Chapter 4
Function Test & Alignment Procedure
4-1

Product

-
H31
4-2

Test Equipment

-
IBM PC with XGA resolution (Color Video Signal & Pattern Generator)
-
VCR with Multi-system(NTSC/PAL/SECAM)
-
Chroma meter Minolta CL-100
-
Chroma 2327 (Pattern Generator)
4-3

Test Condition

-
Circumstance Brightness : Dark room less than 2.5 lux (for Brightness measure)
-
Inspection Distance : 2.5~3m
-
Screen Size : 60 inches diagonal (wide)
-
Before function test and alignment, each H31 should be run-in and warmed-up for at
least 2 hours with following conditions.
1.)
2.)
3.)
-
Test Display Mode & Pattern (Refer to 4-4.1 & 4-4.2)
-

Function Test and Alignment Procedure

Coretronic Corporation
In room temperature
With cycled display colors (R,G,B,White)
With cycled display modes
640*480 (H=37.5 KHz, V=75 Hz)
720*400 (H=31.5 KHz, V=70 Hz)
800*600 (H=53.7 KHz, V=85 Hz)
800*600 (H=37.9 KHz, V=60 Hz)
1024*768 (H=48.4 KHz, V=60 Hz)
1024*768 (H=68.7 KHz, V=85 Hz)
1024*1024 (H=63.98 KHz, V=60 Hz)
4-1
H31