  • Page 1 Enterprise Plus Battery Packs User's Manual...
  • Page 2: Table Of Contents

    Introduction Controls and Indicators Installation Operation Troubleshooting Replacing the Battery Obtaining Service Specifications Limited Product Warranty © Copyright 2006...
  • Page 3: Installation

    SAVE THESE INSTRUCTIONS ! Please read this manual before installing your Enterprise Plus Battery Packs, models EBP36XL, EBP72XL as it provides important information that should be followed during installation and maintenance of the Battery Packs and batter- ies allowing you to correctly set up your system for the maximum safety and performance.
  • Page 4 This symbol indicates "Direct Current Supply" This symbol indicates "Equipment Grounding Conductor" CAUTION! Connect the Battery Pack to a two pole, three wire grounding AC wall outlet. The receptacle must be connected to the appropriate branch protection (circuit breaker or fuse). Connection to any other type of receptacle may result in a shock hazard and violate local electrical codes.
  • Page 5 Battery Pack, the UPS, or the connected equipment caused by the incorrect installation or servicing of the Battery Packs. These Battery Packs MUST be operated with their respective UPS models, see the table below: Model # EBP36XL EBP72XL E750RM2U ED2000RM2U E1000RM2U...
  • Page 6 Receiving Inspection After removing your Battery Pack from its carton, it should be inspected for damage that may have occurred in shipping. Immediately notify the carrier and place of purchase if any damage is found. Warranty claims for damage caused by the carrier will not be honored.
  • Page 7: Rear Panel

    INDICATOR PANEL The Charger Active (green) LED illuminates in a steady state when the Charger is on. The Charger Active LED will extinguish when there is no acceptable AC present. The DC Breaker On (green) LED illuminates in a steady state when the DC breaker is in the On position.
  • Page 8 INSTALLATION PLACEMENT These Battery Packs are intended to be install in a temperature controlled environment that is free of conductive contaminants. Select a location which will provide good air circulation for the Battery Pack at all times. Avoid loca- tions near heating devices, water or excessive humidity, or where the Battery Pack is exposed to direct sunlight.
  • Page 9 RACKMOUNT CONFIGURATION The Battery Pack comes with mounting brackets for the standard 19" (46.5cm) rack. The mounting brackets to fit a 23" (59.2cm) standard rack are also available. The screws for mounting the Battery Pack to the rack are not in- cluded (screw size varies with rack size).
  • Page 10 TOWER CONFIGURATION The tower configuration allows the user to install the Battery Pack in the up- right position next to the UPS and the tower computer. The tower brackets are provided with the Battery Pack. WARNING: Use two or more people when installing the Battery Pack.
  • Page 11 WALLMOUNT CONFIGURATION (continued) 2. Align the mounting brackets with the mounting bracket screw holes and attach with the six retaining screws. 3. Use the template to mark the screw hole position on the wall. CAUTION, you should always were protective gear for your hands and eyes when operating power tools.
  • Page 12 CONNECTING THE BATTERY PACK (QUALIFIED SERVICE PERSONNEL ONLY) NOTE: If you are using these Battery Packs with the Enterprise Plus series UPS, the UPS must be configured so that the UPS will report the correct estimated runtime in the SentryPlus software and to make the Battery capacity bar graph LEDs display properly.
  • Page 13 CONNECTING THE BATTERY PACK TO AN AC SOURCE These Battery Packs can operate with 115VAC or 230VAC input voltage. Be- fore connecting the Battery Pack to an AC Source, verify that the Battery Pack's dipswitch is set for the proper input voltage. 1.
  • Page 14: Operation

    7. Before connecting the Battery Pack to an AC Source, verify that the Battery Pack is set for the proper input voltage. Set the dipswitch on the rear panel of the Battery Pack to the appropriate input voltage. Connect the input power cord with the NEMA 5-15P Plug into the AC Inlet on the first Battery Pack.
  • Page 15 English SYSTEM OVERVIEW These Battery Packs will extend the runtime capabilities of the UPS. These Battery Packs have internal chargers to properly maintain the internal batter- ies. The charger will operate with 115VAC or 230VAC depending on the dipswitch setting. The Battery Pack will charge the batteries with the DC circuit breaker in the On or Off position as long as the Battery Pack is plugged into the AC wall outlet and there is an acceptable AC voltage present (90 - 130VAC/180 - 260VAC).
  • Page 16 What To Do Possible Cause Symptom 1. Plug the input power cord 1. The input power cord is The Charger Active into the AC wall outlet. not plugged into the AC wall LED is not on. outlet. 2. Once commercial power is available recheck the LED.
  • Page 17: Replacing The Battery

    REPLACING THE BATTERY (QUALIFIED SERVICE PERSONNEL ONLY) These Battery Packs have an easy to replace hot-swappable batteries. Please read all of the WARNINGS and CAUTIONS before attempting to service the batteries. NOTE: If there is a power interruption while replacing the hot-swappable batter- ies, the the UPS on, the load will not be backed up.
  • Page 18 Replace the batteries with the same number and type as originally installed in the Battery Pack. These batteries have pressure oper- ated vents. These Battery Packs contain sealed non-spillable maintenance free lead acid batteries. EBP36XL Model # EBP72XL Battery 6-12V7.2Ah 6-12V8.5Ah...
  • Page 19 15. Grasp the other battery pull tab and gently pull the battery module out of the Battery Pack and set on the floor. (FIG. 4) NOTE: Use Caution, the battery modules are heavy. 16. Disconnect the battery positive (red) wires. 17.
  • Page 20 FIG. 2 FIG. 3 FIG. 4...
  • Page 21: Troubleshooting

    IF THE UPS REQUIRES SERVICE 1. Use the TROUBLESHOOTING section to eliminate obvious causes. 2. Verify there are no circuit breakers tripped. A tripped circuit breaker is the most common problem. 3. Call your dealer for assistance. If you cannot reach your dealer, or if they cannot resolve the problem call or fax MINUTEMAN Technical Support at the following numbers;...
  • Page 22: Specifications

    SYSTEM SPECIFICATIONS Model Number EBP36XL EBP72XL Rack/Tower Convertible / Wallmount Format CHARGER INPUT Number of Phases Single (1∅ 2W +G) Nominal Voltage 115/230VAC (dipswitch selectable) Voltage Range 115VAC: 90 - 130VAC (230VAC: 180 - 260VAC) 2.6 Amps AC Current Frequency Limits...
  • Page 23 Para Systems Inc. (Para Systems) warrants this equipment, when properly applied and operated within specified conditions, against faulty materials or workmanship for a period of three years from the date of purchase. For equip- ment sites within the United States and Canada, this warranty covers repair or replacement of defective equipment at the discretion of Para Systems.
  • Page 24: Limited Product Warranty

    LIMITED PRODUCT WARRANTY (Continued) EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL PARA SYSTEMS BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUEN- TIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, Para Sys- tems is not liable for any costs, such as lost profits or revenue, loss of equip- ment, loss of use of equipment, loss of software, loss of data, cost of substi- tutes, claims by third parties, or otherwise.
  • Page 25 Notes:...
  • Page 26 Para Systems, Inc. 1455 Lemay Dr. Carrollton, TX 75007 Phone: 1-972-446-7363 Fax: 1-972-446-9011 Internet: minutemanups.com UPS Sizing: sizemyups.com P/N 34000272...