Vent Configurations
45°
90°
Clean-Out
Tee
Figure 22 - Horizontal and Up 6 Feet
Horizontal installations that terminate without
any vertical sections of pipe are approved;
however, wind may direct flue gases toward
the house causing discoloring problems. For
this reason, horizontal and up 6 feet or hori-
zontal and through the eave installations are
recommended. See Figures 24 and 25.
u
u
Refer to vent manufacturer's installation
instructions for minimum vent clearances.
Figure 23 - Horizontal
A vertical run of 6 feet
is recommended
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Listed Rain Cap
(all installations)
Clean-Out
Tee
Figure 24 - Horizontal and Up Through the Eave
Figure 25 - Wood Stove Pipe Retrofit
Exterior
Vertical Vent
Listed Rain Cap
(all installations)
Interior
Vertical Vent
into an Exist-
ing Class A
Chimney
Vented into
existing 6" or 8"
diameter wood
stove pipe.