Default Boot Sequence; P4000 G2 Unified Nas Gateway Raid Configuration - HP StorageWorks P4000 G2 User Manual

Unified nas gateway
Hide thumbs Also See for StorageWorks P4000 G2:
Table of Contents

Advertisement

IMPORTANT:
The first two logical drives are configured for the storage system operating system.
The Operating System volume default factory settings can be customized after the operating system
is up and running. The following settings can be changed:
RAID level can be changed to any RAID level except RAID 0
OS logical drive size can be changed to 40 GB or higher
If the Operating System volume is customized and the System Recovery DVD is run at a later time,
the System Recovery process will maintain the custom settings as long as the above criteria are met
(RAID level other than RAID 0 and OS logical drive size of 40 GB or higher) and the OS volume is
labeled System. If the storage system arrays are deleted and the System Recovery DVD is run, the
System Recovery process will configure the storage system using the factory default settings listed in
the table below.
HP StorageWorks P4000 G2 Unified NAS Gateways do not include preconfigured data volumes.
The administrator must configure data storage for the storage system. See
storage
on page 68 for more information.
The system reserved partition contains the operating system boot loader and allows you to enable
BitLocker Drive Encryption for the Operating System volume.
Table 3 P4000 G2 Unified NAS Gateway RAID configuration
Model
HP StorageWorks P4000 G2 Unified NAS
Gateway
NOTE:
In the HP Array Configuration Utility (ACU), logical disks are labeled 1 and 2. In Microsoft Disk
Manager, logical disks are displayed as 0 and 1. For HP Smart Array configuration information, see
http://h18004.www1.hp.com/products/servers/proliantstorage/arraycontrollers/.
If the operating system has a failure that might result from corrupt system files, a corrupt registry, or
the system hangs during boot, see

Default boot sequence

The BIOS supports the following default boot sequence:
1.
DVD-ROM
2.
HDD
3.
Bootable USB flash drive
4.
PXE (network boot)
Under normal circumstances, the storage systems boot up from the OS logical drive.
If the system experiences a drive failure, the drive displays an amber disk failure LED.
22
Installing and configuring the server
Logical Disk 1
Operating System Volume
RAID 1+0
Physical Drives 0–1
"System recovery
on page 105.
"Configuring data

Advertisement

Table of Contents
loading

Table of Contents