Culligan Good Water Machine Owner's Manual page 11

Good water machine drinking water system
Table of Contents

Advertisement

Tubing Connectors
The Good Water Machine features easy-to-use push-in
tubing connectors (Fig. 2) on the manifold assembly
and the polishing filter.
To disconnect the connector, hold the collar against
the fitting body and pull the tube from the fitting.
To assemble lubricate the tubing end with water and
push the tubing into the connector until it bottoms out.
Be sure the tubing is smooth and free of abrasions,
otherwise a leak may result.
Filter Replacement and Sanitizing Procedure
Use the following procedure and the reference in Figure 3 when servicing the Good Water
Machine.
Notice: Cleanliness is essential in the filter replacement procedure. Be sure to wash
your hands thoroughly before handling filters. The use of protective gloves is strongly
recommended.
Materials:
Pre-flushed activated carbon cartridge and polishing filter cartridge
Particle filter
Household (5.25%) bleach—hydrogen peroxide is not recommended
Clean 1-gallon plastic container with cap
100-ml graduated cylinder
Plastic pan to hold manifold assembly
Tubing connector, 3/8" tube x 3/8" tube
Flat-blade and #2 Phillips screwdrivers
Paper towels
Disposable plastic gloves (like those used in the food service industry)
Figure 3
Figure 2
Fittings
Flow
Figure 4
Servicing
Your System
(cont.)
9