ritetemp 8082C Install Manual

ritetemp 8082C Install Manual

Hide thumbs Also See for 8082C:

Advertisement

Install guide 8082C
8082C Features
The 8082C can be used with most 24 volt gas, oil or electric heating and air conditioning systems, heat pumps with or without
auxiliary heat, gas millivolt heating systems, or zoned heating systems using air or water control valves. It cannot be used with
120 volt heating systems. Ask The Home Depot for other thermostats to control those systems.
Built in Electro Luminescent backlight gives high visibility of the display in the dark. When using a compressor for heat pump
and/or for air conditioning, a 5 minute delay time protects your compressor from stalling in heat and cool.Two AA batteries are
used to retain your programs and run the thermostat. In addition, the thermostat may be run with AC power if the C wire is
available. The accuracy of the 8082c is +/- 1
to match another thermostat or to compensate for a location.
The 8082c has a humidistat built in to measure and display humidity. It also can be programmed to control high humidity, and/or
low humidity (humidifier required).The 8082c changes the time display to daylight time (DST) by the push of a button.
The 8082c is compatible with dual stage heating systems and heat pumps (with or without auxiliary heat). It also displays the
status of each stage of these systems. If using a heat pump with (expensive) electric auxiliary heat, the 8082c allows you to
choose comfort vs efficiency depending on your location.
In AUTO mode the 8082c is able to automatically switch from HEAT to COOL modes as the weather changes.
Customer Support: 888-515-2585 or Visit our webiste
The 8082C is a very versatile programmable thermostat:
1. The 8082C separately programs each weekday, Sat and Sun for both heat and cool.
2. There are 4 programming periods per day on program (A).
3. In addition, there are 2 or 6 programming periods per day on a 2nd program (B).
4. Each program (A and B) can be programmed separately and easily selected.
5. You can use the built in program for A or B or alter them to suit your life.
6. The programming display and function is so easy to use, it is almost intuitive.
7. You can easily override any program for as little as one period or as long as a vacation.
8. Remote control allows temporary adjustment from w/in 50ft.
The large liquid crystal touch screen display shows: day of the week, time, present
period, present room temperature, target temperature, humidity, and heating or cooling
status. The word FILTER will come on to remind you when the air filter should be changed.
o
F with display resolution of .5
Printed in China
o
F. The room temperature can be changed (calibrated)
www.ritetemp-thermostats.com
ENGLISH
1-402-011

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8082C and is the answer not in the manual?

Questions and answers

Summary of Contents for ritetemp 8082C

  • Page 1 8082C Features The 8082C can be used with most 24 volt gas, oil or electric heating and air conditioning systems, heat pumps with or without auxiliary heat, gas millivolt heating systems, or zoned heating systems using air or water control valves. It cannot be used with 120 volt heating systems.
  • Page 2 Install guide 8082C To avoid electrical shock and to prevent damage to the furnace, air conditioner, Caution and thermostat, disconnect the power supply before beginning work. This can be done at the circuit breaker, or at the appliance. You will need #1 Phillips screwdriver (small) and Tools Drill with 3/16-in.
  • Page 3 • Fill wall opening with non-combustible insulation to prevent drafts. 3 Mount the 8082C • Separate front from back of unit. Press up on the catch on bottom of thermostat and swing the body away from the base, lift up to remove the body from the base.
  • Page 4: Heat Pump Switch

    The batteries will last well over 1 year. If the batteries are not replaced the thermostat will stop working. 2) The 8082C can run on the C wire if available. 24VAC ONLY As shown in the wiring diagrams, The C wire is the other side of the 24VAC heating transformer.
  • Page 5: Wire Connections

    If you have a Zoned Heating/Cooling system with multiple thermostats, please refer to our website at www.ritetemp-thermostats.com for installation notes or call 1-888-515-2585. Before you Connect Wires Please refer back to these guidelines for safe and secure wire connections.
  • Page 6 p u m p F ro m h e a t p u m p F ro m N o rm F ro m h e a t e a t w it h A u x h y s te m tw o s ta g e s w /o A u x h e Go To Page 16...
  • Page 7 2 WIRE Heating (GAS MILLIVOLT or 24vac) a c e F r o m F u r n STEP 1 - Connect the R (or RH) wire to the RH terminal on the thermostat. Thermostat This connects the Heater Power to the thermostat. jumper wire STEP 2 - Connect the W wire...
  • Page 8: Hvac System

    a c e F ro m F u rn STEP 1 - Connect the Y wire to a n d A C u n 4 WIRE NON_HEAT PUMP the Y terminal on the thermostat. This connects to the Cooler Thermostat compressor.
  • Page 9: Heat Pump

    (If you have both O and B contact Comp Power Over Ritetemp or your local HVAC contractor for further Single Stage HEAT PUMP help) This connects the change over valve. STEP 5 - Connect the R wire to the RC terminal on the Thermostat.