Microwave Power Test - Amana CRC21T2 Service Manual

Compact commercial microwave oven
Table of Contents

Advertisement

Test Modes

Microwave Power Test

(TRADITIONAL TEST METHOD)
Test Equipment Needed:
• Amana power test kit R0157397 (Fahrenheit) or
• Menumaster power test kit M95D5 (Centigrade)
1. Fill the plastic container to the bottom of the 1000 ml.
lines with cool tap water.
2. Using the thermometer; Fahrenheit or Centigrade,
stir the water, measure and record the water
temperature. IMPORTANT: Initial water
temperature should be approximately 60°F (20°C).
3. Place the container on the center of the oven shelf
and heat the water for 63 seconds for ovens rated
less then 1550 watts or 33 seconds for ovens with
more then 1550 watts of power.
ONE MINUTE, THREE SECONDS run time chart for units less than 1550 watts cooking power.
T
Cooking
(°F)
Power Output
12
464
13
504
14
542
15
581
16
620
17
659
18
697
19
736
20
775
21
814
22
852
23
891
24
930
25
969
26
1007
THIRTY THREE SECONDS run time chart for units more than 1550 watts cooking power.
T
Cooking
(°F)
Power Output
20
1550
21
1627
22
1705
23
1782
24
1860
25
1937
26
2015
27
2092
RS2230003 Rev. 1
Temperature Chart
T
Cooking
(°F)
Power Output
27
1046
28
1085
29
1124
30
1162
31
1201
32
1240
33
1279
34
1317
35
1359
36
1395
37
1434
38
1472
39
1511
40
1550
T
Cooking
(°F)
Power Output
28
2170
29
2247
30
2325
31
2402
32
2480
33
2557
34
2635
35
2712
22
NOTE: Use a watch second hand, not the oven timer.
4. Stir the water, measure and record the temperature
of the water after heating time is completed.
5. Subtract the starting water temperature (Step 2) from
the ending water temperature (Step 4) to obtain the
temperature rise.
6. Refer to the Temperature Chart.
NOTE: Variation or errors in the test procedure will
cause a variance in the temperature rise
indication. Additional power tests should be
made if temperature rise appears marginal.
NOTE: Low line voltage may cause lower power output
(temperature rise).
NOTE: Always perform 3 tests for accuracy. Change
water after each test
T
Cooking
(°C)
Power Output
7
490
8
560
9
630
10
700
11
770
12
840
13
910
14
980
T
Cooking
(°C)
Power Output
11
1540
11.5
1610
12
1680
12.5
1750
13
1820
13.5
1890
14
1960
14.5
2030
15
2100
T
Cooking
(°C)
Power Output
15
1050
16
1120
17
1190
18
1260
19
1330
20
1400
21
1470
22
1540
T
Cooking
(°C)
Power Output
15.5
2170
16
2240
16.5
2310
17
2380
17.5
2450
18
2520
18.5
2590
19
2660
19.5
2730