Roland V-Drums V-Pad PD-80R Owner's Manual page 2

Hide thumbs Also See for V-Drums V-Pad PD-80R:
Table of Contents

Advertisement

Recommended Settings for the Percussion Sound Module
Recommended settings for the trigger parameters when using the PD-80/PD-80R with various percussion sound
modules.
When used with a percussion sound module capable of positional sensing, you can obtain tonal changes by varying the location
at which the pad is struck.
You can perform rim shots and cross-sticking with the PD-80R. For information on sound generator and trigger input
combinations, refer to p. 6.
The trigger parameters should be adjusted as necessary to match the actual state of your configuration, and the environment in
which it is being used.
For information on how to change the parameters for a percussion sound module. Refer to the documentation for the percussion
sound module you're using.
TD-10 (TDW-1 V-Cymbal Control, TDW-1)
Trigger Type
Sensitivity
Threshold
Curve
Scan Time
(*1) 1.8
Retrigger Cancel
(*1) 4
Mask Time
(*1) 8
Xtalk Cancel
(*1) 50
Mount Type
(*1) PadMount
Xstick Thrshld
Rim Sens
TD-10 (Non expanded)
Trigger Type
Sensitivity
Threshold
Curve
Scan Time
(*1) 1.8
Retrigger Cancel
(*1) 3
Mask Time
(*1) 12
Xtalk Cancel
(*1) OFF
Rim Sens
TD-8
TRIGGER TYPE
SENSITIVITY
THRESHOLD
CURVE
RIM SENS
SCAN TIME
RETRIGCANCL
MASK TIME
CROSSTALK
CROSS STICK
TD-6V
TrigType
Sensitivity
Threshold
TrigCurve
Xtalk Cancel
Scan Time
Retrig Cancel
Mask Time
Rim Sens
*1: You need to set each advanced trigger parameter after setting the trigger type.
*2: Each trigger parameter can be set independently for the "head-side" and "rim-side." Set to the same value for the head and rim.
Trigger parameters can be set individually for each patch.
PD-80: 8 A or 8 B, PD-80R: 8RA or 8RB
5
2
Linear
75 (PD-80R only)
8 (PD-80R only)
12A
3
1
Linear
8 (PD-80R only)
PD-80: 8 A or 8 B, PD-80R: 8RA or 8RB
7
3
LINEAR
8 (PD-80R only)
PD-80R: 2, PD-80: 1
3
0
45
5 (PD-80R only)
PD-80: PD80/100, PD-80R: PD80R
8
PD-80R: 3, PD-80: 1
LINEAR
40
1.0
3
4
11 (PD-80R only)
TD-7
(*2)
Cross Talk Group
Velocity Curve
Choke
Max Dyna
MIn Dyna
Min Velo
Mask Time
Threshold
TD-5
TRIGGER TYPE
SENSITIVITY
THRESHOLD
CURVE
SPD-20
TRIG SENS
TRIG THRESHOLD
TRIG TYPE
TRIG CURVE
RIM SENS
SPD-11
Trig Sens
Trig Threshold
Trig Mask Time
Trig Scan Time
SPD-S
Input Mode
Trigger Type
Sensitivity
Threshold
Velocity Curve
Scan Time
Retrigger Cancel
Mask Time
Xtalk Cancel
Rim Sensitivity
Rim Gain
HPD-15
Input Mode
Trig Type
Trig Sens
Curve
Threshold
Scan Time
Retrig Cancel
Mask Time
X-Talk Rate
Rim Sens
2
OFF
Norm3
OFF
5
9
1
0
1
P1
4
1
Lnr
8
0ß40
120
1
1 (PD-80R only)
8
1
0
20
PD-80: TRIGx2, PD-80R: HD/RM
PD-80: PD-80/100, PD-80R: PD-80R
8
PD-80: 3, PD-80R: 2
LINEAR
1.0
PD-80: 4, PD-80R: 3
4
30
11 (PD-80R only)
1.2 (PD-80R only)
PD-80: TRIGx2, PD-80R: HD/RM
PD-80: PD-80, PD-80R: PD-80R
8
Linear
2
1ms
2
2ms
50%
8 (PD-80R only)

Advertisement

Table of Contents
loading

This manual is also suitable for:

V-drums v-pad pd-80