OPERATING INSTRUCTIONS
REMOTE PANEL
Starting the Generator
To start the generator, hold the momentary ON switch in the
up (on) position (the green light will come on), then hold the
momentary START/STOP switch in the up (start) position
(both switches are held up together). After approximately onc
second. the starter will engage and the engine will crank {the
green light
will
dim). Once the en'gine is running (the green
light will brighten», the starter will disengage, and the
START/STOP switch may then be released to return to its
center (run mode) position. Continue holding the ON switch
until the engine has sufficient oil pressure,
then 'release
it
to
its center position.
NOTE:
Should the engine fail to start, release both switches,
wait 20 seconds, and
try
again. Never run the starter more
than 20 seconds at a time.
_<>
START
--
/
--
/
/
I]~'v::/==::::O
OFF/RUN
__ <,-'
START
............
;~/"
STOP OFF
START ISTOP SWITCI/
ON SWITCH
Stopping the Generator
To stop the generator, move the momentary START/STOP
switch to the down
(stop)
position then release it to the center
(off/run mode) position. This will de-energize the K2 run
relay in the generator's control panel and stop the generator.
WESTERBEKE