OPERATING INSTRUCTIONS
START SWITCH
GENERATOR CONTROL PANEL
F1 FUSE
·DC CIRCUIT
·BREAKER
ON/OFF
. LED FAULT
INDICATOR LIGHTS
The start/stop rocker switch is the only functional component
on the generator control panel used to start and stop the
·
generator.
The start/stop rocker switch is a
three
position switch with
momentary contacts in the
(START)
and
(STOP)
position and
a stationary contact function in the center (NORMAL) this
position allows the generator to run once started and also
enables the remote start/stop panel(s) to control the start/stop
functions of the genemtor.
The
(START)
position starts the generator and once released
reverts to the center position. The
(STOP)
position stops the
engine in normal operation as well as in an emergency
situation. This position opens the K2 run relay which
de-energizes the engine's run. circuit and shuts down the :engine.
Starting
Simply press the
(START)
switch momentarily. The ECU will
take the command and start the generator. The green LED on
the start switch will illuminate and
dim
as the engine cranks
and glow bright once the engine starts.
Stopping
oepress ihe
(STOP)
switch momentarily and release. The
ECU will receive the
(STOP)
command and shut the
generator down.
Failure to Start
The start cycle will automatically terminate
if
the unit fails to
start after 6 seconds (approximately) of cranking time. The
fault LED for ''Underspeed" will illuminate and flash. To
initiate another another crank cycle, the panel DC breaker
must be.
turned
OFF
and then back
ON.
·
•·
REMOTE START/STOP PANEL
The components on the panel are:
1. A
three
position start/stop rocker switch.
2. A green LED run indicator light on the rocker switch.
3. A four position LED fault shut.down display board.
The start/stop rocker switch functions the same as the start/stop
rocker switch on the generator's control panel as previously
explained.
The green LED run indicator light on the rocker switch will
illuminate when the start circuit is energized.
It
will go
dim
as
the engine
cranks
and will brighten as the engine starts
indicating the generator is running.
The LED fault shut down display board has four separate LED
lights to display to the operator the cause of the generators
automatic shut down. The four LED displays are: low oil
pressure, high engine operating temperature, high exhaust
temperature and engine over-speed/under-speed (flashes).
Should the generator shut down from one of these faults, the
fault LED will remain illuminated. To reset- the LED, the DC
breaker
must
be turned
OFF
and then back
ON.
The remote start/stop panel is a plug-in accessory and has
extension harnesses available in varying lengths from 15 feet
up to lOOfeet in length.
1+-----3.35----~
0
0
fW'JWESTERBEKE
T
START·----.STOP
0
Engines & Generators