CONTROL PANELS
GENERATOR CONTROL PANEL
The ON and START/STOP switches are the only functional
components to operate the generator at the engine. Both
switches are used to start the generator - see Starting the
Generator under OPERATING INSTRUCTIONS.
The ON switch is a two-position switch with momentary
contacts in the up (on) position and a stationary contact
function in the center position. This switch energizes the
fuel pump.
The START/STOP switch is a three-position switch with
momentary contacts in the up (start) position and a stationary
contact function in the center and down (stop) positions. The
center (normal) position allows the generator to be run, once
started, and also enables the remote panel(s) to control the
start/stop functions. The up (start) position starts the generator
and once released, reverts to the center position. The down
(stop) position stops the engine in nonnal operation as well
as in an emergency situation, as it opens the K2 relay which
de-energizes the run circuit and shuts down the engine
(unlike the remote panel stop switch) controls power to the
starter, fuel pump, and ignition relay coils, thus stopping the
engine should a malfunction occur. During times when
maintenance is being performed on the generator, the
START/OFF switch should be placed in the stationary (off)
position. This will disable the remote control panel(s), pre-
venting attempts to start the generator from their locations.
However, it is always best to remove the Fl fuse to prevent
accidental starting .
REMOTE PANEL
There are three functional components on the remote panel
for generator operation:
1. ON switch
1. START/STOP switch
2. Green LED indicator light
The ON switch is a two-position switch with momentary
contacts in the up (on) position and a stationary contact
function in the center PQsition. This switch energizes the
fuel pump.
The START/STOP switch is a three-position switch with
momentary contact functions in the up (start) and down
(stop) positions, and a stationary contact function in the
center position The center position
i~
a dual OFFIRUN mode
position and is nonnally in the off mode. When in the start
(up) position, this switch starts the generator (together with
the ON switch in the up position) and once released, reverts
to the center position, run mode. When in the stop (down)
position, this switch stops the generator, and once released,
reverts to the center position, off mode.
The Green LED indicator light indicates the engine running
condition. It lights when the ON switch is moved to the start
position, dims when the engine is cranking, and brightens
when the engine starts, notifying the operator to release the
START switch.
~+--IHOUR
METER
RESET BUTTON
ON SWITCH
----IL.lo..J
START/STOP SWITCH: CENTERED,
THIS SWITCH IS IN THE OFF
POSITION. ONCE THE GENERATOR
IS STARTED, THE CENTER POSITION
BECOMES THE RUN POSITION.
"",=--~--
F1 FUSE
REMOTE PANEL
CONNECTION
I
REMOTE PANEL
NOTE:
Refer to OPERATING INSTRUCTIONS
in the following pages for the operation
of these panels.